Menu 4
4-6 Steam Temperature
Steam auto
0070 C
4-7 Steam Time
Steam manual
060.0 sec
4-9 Bypass Quantity
x Coffee
<- Grinder
000 %
4-20 Milk Percent
x Cappuccino
<- Grinder
00%
4-2 Product number
x Expresso
<- Grinder
000
© 2006 by Thermoplan, Subject to change
Technical Manual
In menu 4-6 you can adjust the temperature of the steam auto with the Plus-/Minus levers.
The Steam switched after the adjusted temperature automatically off.
In menu 4-7 you can decided the time for the manual steam-reference.
The manual steam switched after the adjusted temperature automatically off.
In menu 4-9 you can adjust the desired bypass quantity in % with the Plus-/Minus levers. Is the value 000%, than
is the bypass inactive.
For example: Coffee product 020%: 20% bypass -> 80% goes though the brew chamber.
By Press and hold the enter key for 2 sec, so you can source a test product.
In menu 4-20 you can adjust the desired milk precent with the Plus-/Minus levers.
For example: milk product 00%: 0% milk and 90% milk foam.
By Press and hold the enter key for 2 sec, so you can source a test product.
In menu 4-2 you can set the product number for each coffee product with the Plus-/Minus levers.
This menu appears only if menu 6-23 „Interface Option" is activated.