The Display Menu
Display Options Field
To specify a Scope Channel Label, touch the field corresponding to the
oscilloscope input you wish to label. The default Scope Channel Labels are
the cardslot and input number you see elsewhere on the oscilloscope menus.
When you touch one of the channel label fields, an alpha-numeric keypad
will appear on screen. If you need to change a character in the Scope
Channel Label, you can use the knob to move the cursor to the desired
position. Scope Channel Labels are limited to five characters in length. The
Clear field will erase the entire label. When you are finished specifying the
label, touch Done to exit the keypad.
When all channels have been labeled, touch the Done field to return to the
oscilloscope menu. Any oscilloscope channels you don't label will retain
their default label (cardslot and input number). To erase all scope channel
labels for the oscilloscope, and return to the default oscilloscope channel
labels, simply touch the Default field on the Scope Channel Labels menu.
Display Sample Period
Selecting the Display Sample Period option will cause the sample period
information (see Sample Period Display in the Time Base Functions chapter)
to be displayed on the scope menus. Sample period information is the
default display option and is always displayed when markers are turned off.
Display Marker Values
Selecting the Display Marker Values option will cause the marker value
information (see Marker Value Display in the Marker Options chapter) to be
displayed on the oscilloscope menus. Marker values can only be selected
when at least one of the markers have been enabled.