Download Print this page

Viking 1600-IP Series Product Manual page 21

Ada compliant voip emergency phones
Hide thumbs Also See for 1600-IP Series:

Advertisement

D. Configuring E-1600-IP VLAN Settings
Step 1.
Click on the "VLAN" tab
Step 2.
Disable or enable VLAN tagging by setting the value of "VLAN Tagging".
Step 3.
Set the VLAN tag ID by selecting an integer (1 to 4094) in "ID for all packets".
Set the Priority Code Point (PCP) value for all not SIP and RTP packets in the "PCP for all packets" input (0 is default, priorities are
Step 4.
from low to high: 0, 1, 2, 3, 4, 5, 6, 7). Set the "PCP for SIP packets" (3 is default). Set the "PCP for RTP packets" (5 is default).
E. Manually Resetting the Security Code to Enter Programming
Step 1.
Power down the 1600-IP Series phone by disconnecting the LAN Cable (RJ45 plug).
Step 2.
Press and hold the Call button, then reconnect the LAN Cable (RJ45 plug).
Continue to hold Call button until you hear 2 beeps, (approximately 6 seconds). Then release the button. The LED will remain off for
Step 3.
the first 3 seconds, flash slowly for 3 seconds then fast flash (after 2 beeps), indicating when to release button.
Step 4.
The security code is now reset to 845464 (factory default).
Step 5.
You can now enter programming by following the steps in section A.
F. Manually Resetting All Network Parameters to Factory Default
Step 1. Power down the 1600-IP Series phone by disconnecting the LAN Cable (RJ45 plug).
Step 2. Press and hold the Call button, then reconnect the LAN Cable (RJ45 plug).
Continue to hold t he Call button until you hear 2 beeps, (approximately 6 seconds). Continue to hold Call button until you hear 4 more
Step 3.
beeps, approximately 6 seconds later, then release the button. The LED will remain off for the first 3 seconds, flash slowly for 3
seconds (2 beeps), fast flash for 6 seconds (4 beeps), then light steady indicating when to release button.
Step 4. You can now enter programming by following the steps in section A.