The 1600A Series ADA Compliant Emergency Phones are designed
to provide quick and reliable handsfree communication for any stan-
dard analog telephone line or analog phone system station port. All
1600A Series phones meet ADA requirements for elevator/ emer-
gency telephones, and can be programmed from any Touch Tone
phone. The phones can dial up to 5 programmable emergency num-
bers, as well as 2 central station num-
bers. In addition, the E-1600-20A and
E-1600-52A feature a second "INFO"
button that will dial up to 3 non-emer-
gency numbers.
The 1600A Series phones can be pro-
grammed to automatically deliver a
digital announcement to identify the location of the emergency call. Alternatively, a DTMF Touch Tone code may also be delivered.
A "Call Connected" LED can be initiated manually or automatically. All programming parameters, including phone numbers and
location numbers, are stored in non-volatile E
and are compatible with common Central Station Monitoring equipment.
For outdoor installations where the unit is exposed to precipitation or condensation, select 1600A Series phones are available with
Enhanced Weather Protection (EWP). EWP products feature foam rubber gaskets and boots, sealed connections, gel-filled butt
connectors, as well as urethane or thermal plastic potted circuit boards with internally sealed, field-adjustable trim pots and DIP
switches for easy on-site programming. For more information, see DOD# 859.
F
e
a
t
u
r
e
s
F
e
a
t
u
r
e
s
• New Automatic Noise Canceling (ANC) feature for proper operation
in noisy environments
• Meets the latest ASME A17.1 code when used with the optional LV-1K
Line Verification Panel, see DOD# 246
• Meets ADA requirements for Emergency Phones:
- Automatically lights the "Call Connected" LED
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired
• Non-volatile digital voice announcer with 16 seconds of voice memory
• Advanced call progress detection
• Handsfree operation
• Phone line powered
• Non-volatile memory (no batteries required)
• Marine grade 316 stainless steel prevents corrosion on stainless models
• Dials up to 5 emergency numbers
• E-1600-20A and E-1600-52A dial up to 3 non-emergency "INFO" #'s
• Cycles through backup phone numbers on busy or no-answer
• Optional Enhanced Weather Protection (EWP), EWP products are
designed to meet IP66 Ingress Protection Rating, see DOD# 859
• Hangs up on CPC, silence, busy signal, dial tone, time-out or touch
tone command
• Programmable to auto-answer on incoming calls
• Remotely programmable
• Extended temperature range (-15°F to 130°F)
• 9 different chassis or board only available
• Available in 42" tall tower phone model E-1600A-BLT-EWP (DOD# 217)
• Central Station Monitoring capability (dials 2 numbers)
• Optional PB-100 Polling System available (DOD# 232)
• Optional BLK-3-EWP strobe light kit available (DOD# 653)
• Optional LC-6 Six Port Concentrator available (DOD# 245)
• Optional LV-1K Line Verification Panel available (DOD# 246)
• Optional E-1600A-MK-GNP Pedestal Mounting Kit (DOD# 227)
• Optional PB-1 Panic Button Kit (DOD# 233)
S
S
C
O
M
O
L
U
T
I
O
N
S
C
O
M
O
L
U
T
I
O
N
S
ADA* Compliant Emergency Phones with
Built-In Digital Voice Announcer
P
r
a
c
P
r
a
c
2
1
C
2
1
C
F
O
R
T
H
E
S
T
F
O
R
T
H
E
S
T
E-1600-65A
E-1600A
E-1600-45A
2
memory. All units are phone line powered, requiring no batteries or external power
A
p
p
l
i
A
p
p
l
i
• Elevators
• Parking ramps/lots
• Emergency pool phones
• ATM machines
• Area of refuge locations
• Lobbies
• Entryways
• Campus emergency stations
• Roadside emergency stations
• Stadiums
• Convention centers
• Silent holdup alarm dialer using optional Panic Button Kit
* Americans with Disabilities Act of 1992 contains federal reg-
ulations regarding elevator telephones (Public Law 101-336).
S
p
e
c
S
p
e
c
Power: Telephone line powered. Minimum 24V DC talk battery voltage,
with a minimum loop current of 20mA loop. Loop current may be boosted
on low current lines with a Viking Model TBB-1B talk battery booster, see
DOD# 632.
Dimensions: See Installation and Specifications
Operating Temperature: -26° C to 54° C (-15° F to 130° F)
Humidity - Standard Products: 5% to 95% non-condensing
Humidity - EWP Products: Up to 100%
CAUTION - When installing on an analog extension of a phone system:
Some phone systems do not conform to analog telecom standards and might
not be compatible with the 1600A Series emergency phones. For a detailed
description of the telephone line specifications required for any of the 1600A
Series phones, see DOD# 869.
1600A Series
1600A Series
ADA Compliant
t
i
c
e
t
i
c
e
Emergency Phones
September 10, 2015
E
N
T
U
R
Y
E
N
T
U
R
Y
E-1600-02A
K-1600-EHFA
E-1600-60A
E-1600-30A
c
a
t
i
o
n
s
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
E-1600-03B
E-1600-55A
E-1600-20A

Advertisement

Table of Contents
loading

Summary of Contents for Viking E-1600-03B

  • Page 1 20mA loop. Loop current may be boosted • Programmable to auto-answer on incoming calls on low current lines with a Viking Model TBB-1B talk battery booster, see • Remotely programmable DOD# 632.
  • Page 2 Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase from any authorized Viking distributor.
  • Page 3 MK-GNP Mounting Kit (DOD# 227) allows you to mount the E- Mounting: Surface mount to walls, posts, single gang boxes or 4” 1600A, E-1600-40A, E-1600-45A, E-1600-60A or E-1600-65A to x 4” electrical junction boxes or recess mount in elevator phone a Viking VE-GNP Gooseneck Pedestal (DOD# 424). boxes. POLICE 3.40 4.00...
  • Page 4 Mounting with Optional VE-5x5: Surface mount to walls, single gang boxes, dou- brushed stainless steel ble gang boxes, posts, or to a Viking VE-GNP Gooseneck pedestal (see options below). Connections: Gel-filled butt connectors Note: When mounting outside to rough or uneven surfaces (brick, stucco, etc.) apply a bead of clear silicone caulking around the top edge and sides of faceplate or VE-5x5.
  • Page 5 0.795 (4) .187 x .50 (sealed per IP67) Push To Call Button slots for double gang box VIKING MODEL E-1600-03B © 1.70 0.80 (2) .187 x .50 2.605 slots for single 8-32 x .5" set 3.40...
  • Page 6: Accessing The Programming Mode

    Step 5. When finished programming, move DIP switch 3 back to the ON position (see section J). Warning: Failure to do step 5 above will cause the 1600A Series phone to call Viking Technical Support instead of your programmed emergency number.
  • Page 7: Speed Dial Numbers

    C. Quick Programming Features Enter Digits - then - Enter Memory Location First emergency speed dial number ................. 0-20 digits then Second emergency speed dial number ..............0-20 digits then Third emergency speed dial number ............... 0-20 digits then Fourth emergency speed dial number ..............0-20 digits then Fifth emergency speed dial number .................
  • Page 8 F. Timing/Dialing Options (memory location #18) There are six positions in the timing/dialing options. To program these options, enter the six desired timing/dialing num- bers followed by #18. The six available timing/dialing options are defined as follows: Dial: A + B + C + D + E + F + # + 1 + 8 Enter Timing/Dialing Settings Here: Factory Default Setting: 2 + 3 + 4 + 7 + 2 + 1 Talk/Listen Delay...
  • Page 9: Recording The Announcement

    G. Voice Announcer/Miscellaneous Options (memory location #17) The 1600A series phones have a built-in non-volatile digital voice announcer that may be used to identify the location of the emer- gency phone call. The 16 seconds of digital record time is recorded remotely from a Touch Tone phone. Programming options are as follows: Dial: A + B + C + D + E + F + # + 1 + 7 Factory Default Setting: 0 + 0 + 1 + 2 + 1 + 0...
  • Page 10 "dial 9" PBX. The 1600A Series phone will first dial 9, and then listen for second dial tone; if detected it will continue to dial Viking’s assisted pro- gramming phone number. If a second dial tone is not detected, it then knows is not behind a PBX, so it will momentarily hang up and then directly dial Viking’s assisted programming phone number.
  • Page 11 d. Speed Dial Numbers The 1600A Series phone can be programmed to dial a central station receiver only, or dial up to 5 voice numbers first, and if no answer, then dial the central station receiver. When calling the first numbers (memory positions #00-#04 (see Programming section D), the phone stays in “two-way talk mode”...
  • Page 12: Standard Operation

    #06 if programmed. Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.