C O M M U N I C A T I O N & S E C U R I T Y S O L U T I O N S
ADA Compliant Tower Phones with Blue
Steady On LED Beacon and Strobe Light
Viking Tower Phones provide added safety for your patrons, employees, and students with the
addition of high visibility, ADA compliant communication. At the simple push of a button, the
E-1600A-AST-EWP or E-1600A-BLT-EWP will initiate a call to your personnel and send a
digital announcement to identify the location of the call. In addition, the tower phone's bright
LED strobe light will instantly begin flashing to deter further activity and make it fast and easy
for Police or Security personnel to locate the site of the call. The strobe light can also be
programmed to provide a continuous-on lower intensity beacon when the phone is not in use.
Though the strobe requires external power to operate, rest assured that communication is
possible, even during power failures! All phone numbers, location numbers and programming
parameters are stored in non-volatile memory. No batteries are required to hold the memory.
These tower phones are equipped with Enhanced Weather Protection (EWP) for outdoor
installations where the unit is exposed to precipitation or condensation. EWP products feature
foam rubber gaskets, sealed connections, gel-filled butt connectors, as well as urethane or
thermal plastic potted circuit boards with internally sealed, field-adjustable trim pots and DIP
switches for easy on-site programming. For more information on EWP, see DOD 859.
Features
• New Automatic Noise Canceling (ANC) feature for proper
operation in noisy environments
• Enhanced Weather Protection (EWP), EWP products are designed
to meet IP66 Ingress Protection Rating (DOD 859)
• Meets ADA requirements for Emergency Phones:
- Automatically lights the "Call Connected" LED
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired
• 16 second non-volatile digital voice announcer
• High power LED strobe and beacon visual indicator:
- High output / long life LED technology
- 4 programmable flash patterns: single, double, quad and flicker
- 6 programmable beacon and strobe brightness settings
• Advanced call progress detection
• Handsfree operation
• Phone line powered emergency phone (strobe requires power)
• Non-volatile memory (no batteries required)
• Marine grade 316 stainless steel and powder coated aluminum to
prevent corrosion
• Dials up to 5 emergency numbers
• Cycles through backup phone numbers on busy or no-answer
• E-1600A-AST2EWP and E-1600A-BLT2EWP can also dial up to 3
"Info" numbers
• Hangs up on CPC, silence, busy, dial tone, time-out or touch tone
• Programmable to auto-answer on incoming calls
• Remotely programmable
• Central Station Monitoring capability (dials 2 numbers)
• Separate central station voice speed dial number
• Optional PB-100 Polling System available (DOD 232)
PRODUCT MANUAL
• Campus Auditoriums
• Parking Ramps/Lots
• Automated Tellers (ATM)
CAUTION - When installing on an analog extension of a phone system: Some phone
systems do not conform to analog telecom standards and might not be compatible with the
1600A Series Emergency Phones. For a detailed description of the telephone line specifications
required for any of the 1600A Series phones, retrieve DOD 869.
Phone Power: Telephone line powered. Minimum 24V DC talk battery voltage,
with a minimum loop current of 20mA. Loop current may be boosted on low
current lines with a Viking Model TBB-1B talk battery booster (DOD 632).
Beacon/Strobe Power: 120V AC / 12V DC power adapter (included)
Maximum Strobe Power Run: 200 feet using 24 AWG wire
Dimensions: 42" x 6" x 4.5" (1070mm x 152.4mm x 109.3mm)
Shipping Weight: 20 lbs (9.1 kg)
Mounting: Surface mount to rigid wall or post
Operating Temperature: -15°F to 130°F (-26°C to 54°C)
Humidity: Up to 100%
Strobe Flash Rate: 60 flashes per minute (default), see page 7 for more info
Maximum Strobe Light Output @ 15VDC: Clear lens: 323 lumens, Amber
lens: 242 lumens, Blue lens: 116 lumens, Red lens: 66 lumens
Maximum Power Supply Run Length on CAT-5: 1 pair = 125 ft, 2 pair =
225 ft, 3 pair = 325 ft, 4 pair = 475 ft
Enclosure Material: 0.125" aluminum, 3" x 6" (76.2mm x 152.4mm) tube,
powder painted high-visible yellow
Phone Panel Material: 0.074" (14 gauge) 316 marine grade stainless steel
with stainless steel button
Strobe Material: Vandal resistant polycarbonate plastic
Connections: Color-coded wires with gel-filled butt connectors
Tower Phones
ADA Compliant
Emergency Tower Phones
February 26, 2019
E-1600A-BLT-EWP
E-1600A-BLT2EWP
E-1600A-AST-EWP E-1600A-AS T2EWP
Applications
• Entryways
• Stairwells in Public Buildings
Specifications

Advertisement

Table of Contents
loading

Summary of Contents for Viking E-1600A-BLT-EWP

  • Page 1 ADA Compliant Tower Phones with Blue Steady On LED Beacon and Strobe Light Viking Tower Phones provide added safety for your patrons, employees, and students with the addition of high visibility, ADA compliant communication. At the simple push of a button, the E-1600A-AST-EWP or E-1600A-BLT-EWP will initiate a call to your personnel and send a digital announcement to identify the location of the call.
  • Page 2: Features Overview

    IP67. “HELP” Push to Call Button: Solid 316 CALL stainless steel internally sealed per IP67. CONNECTED VIKING © Grade 2 Braille Label Red Call Connected LED Mounting Screws: (4) T-10 Torx head stainless steel, flat head, security screws and drive bit included.
  • Page 3 CONNECTED PUSH FOR HELP VIKING © Phone Panel “ASSISTANCE” on models E-1600A-AST-EWP E-1600A-AST2EWP “ASSISTANCE” on models “EMERGENCY” on models E-1600A-AST-EWP 0.125 E-1600A-BLT-EWP E-1600A-AST2EWP E-1600A-BLT2EWP Knockout for 1/2 inch conduit 4.750 5.000 2.87 “EMERGENCY” 1.50 on models 1.37 Bottom E-1600A-BLT-EWP E-1600A-BLT2EWP 0.75...
  • Page 4 Rear View of Legacy Red with SL-1 Strobe Light Incoming Yellow stripe (included with 2012 and older Analog E-1600A-BLT-EWP models) Phone Line Red (+) Green with Yellow stripe Black (-) Note: Not polarity sensitive. Green (see section F page 6)
  • Page 5 BLK-4 Control Module Programming BLK-4 Control Module A. DIP Switches Switch 1 Switch 3 Description (see section B) Ring Detection Only Off-Hook/Loop Current Detection Only Ring and Off-Hook/Loop Current Detection Switch 2 Ring Cadence Mode (see section C) Ring Cadence Mode ON - relay remains activated in between rings Ring Cadence Mode OFF - relay is activated only during ringing Switch 4 Auxiliary Relay Contacts (see section D) Wet (12VDC, 100mA maximum)
  • Page 6 F. Switched 12V DC Output The switched 12V DC output is a low current, 12-15VDC output that is turned on only while the trigger input is closed or ring/loop detect relay is activated. This switched power output is ideal for triggering the included strobe light or providing 12-15V DC power to any device that draws less than 400mAmps.
  • Page 7: Operation

    C. Programming Features List Feature Description Feature Description Beacon/Strobe (factory default) Single Flash Strobe (factory default) Strobe Only Double Flash Strobe Beacon Only Quad Flash Strobe Strobe Brightness 1-6 (factory default = 6, brightest) Flicker Flash Strobe Beacon Brightness 1-6 (factory default = 6, brightest) Reset to Factory Default Settings D.
  • Page 8 When finished programming, move DIP switch 3 back to the ON position (see section J). Warning: Failure to do step 5 above will cause the 1600A Series phone to call Viking Technical Support instead of your programmed number. See Section I, Assisted Programming.
  • Page 9: Security Code

    C. Security Code (memory location #19) The security code allows the user/installer to program the 1600A series phone while DIP switch 3 is in the ON (normal) position. The factory set security code is 845464 (V-I-K-I-N-G). It is recommended that the factory set security code be changed.
  • Page 10 F. Timing/Dialing Options (memory location #18) There are six positions in the timing/dialing options. To program these options, enter the six desired timing/dialing numbers followed by #18. The six available timing/dialing options are defined as follows: Dial: A + B + C + D + E + F + # + 1 + 8 Enter Timing/Dialing Settings Here: Factory Default Setting: 2 + 3 + 4 + 7 + 2 + 1 Talk/Listen Delay...
  • Page 11 Setting E - Dial Next Number on Busy If enabled and a busy is detected, the 1600A series phone will dial the next Touch Tone Setting E programmed speed dial number, and continue to cycle through the numbers until Disabled a call is completed.
  • Page 12: Recording The Announcement

    CO line, or behind a "dial 9" PBX. The 1600A Series phone will first dial 9, and then listen for second dial tone; if detected it will continue to dial Viking’s assisted programming phone number. If a second dial tone is not detected, it then knows is not behind a PBX, so it will momentarily hang up and then directly dial Viking’s assisted programming phone number.
  • Page 13 Learn mode - Any incoming calls are automatically entered into the programming mode (no security code required). Use this option if you have forgotten your security code. Any outbound call will dial Viking Technical Support (see section I). Warning: When OFF ON...
  • Page 14 d. Speed Dial Numbers The 1600A Series phone can be programmed to dial a central station receiver only, or dial up to 5 voice numbers first, and if no answer, then dial the central station receiver. When calling the first numbers (memory positions #00-#04 (see Programming section D), the phone stays in “two-way talk mode”...
  • Page 15: Standard Operation

    d. 4+2 Express Format This DTMF format consists of a four digit account code, two digit message type, and a two digit event code. XXXX 27 XX #20 Memory Location Account Code Event Code Message Type Enter 4+2 Express ID Settings Here: Operation A.
  • Page 16: Warranty

    TWO YEAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016.

This manual is also suitable for:

E-1600a-as t2ewpE-1600a-ast-ewpE-1600a-blt2ewp

Table of Contents