Technical Data; Pre-Conditions / Basis For Calculation; Torques - Kessel EasyClean free NS 2 Installation, Operation And Maintenance Manual

Hide thumbs Also See for EasyClean free NS 2:
Table of Contents

Advertisement

5

Technical data

5.1

Pre-conditions / basis for calculation

The parameters for operation (emptying) of the grease separator system are based on the following values:
– Pumping quantity (extraction capacity) of the disposal vehicle 10 l/s = 36 m³/h.
– Cold / hot water supply 1l/s with DN25
– Room temperature at least +15° C.
Cold water requirement
(inlet edge outlet assembly)
Note: the value corresponds to the volume of the separator chamber plus the volume of the sludge trap.
Since the products described are customised versions, where the dimensions are produced in accordance with
customer wishes, there can be minor deviations in the volumes.
5.2

Torques

Description / use
Door hinge screw A2 bright 6x40
PT-screw 100x30 A2
PT-screw KB60x30 WN 1411
Metal clamp / on system tank
Hexagon safety screw M8x30
Pipe clamp D=120
Pipe clamp D=84
PT-hexagon screw K80x40 WN 1447
2018/01
Technical data
NS 2
NS 4
NS 7
410
750
1270
15 / 18
NS 10
NS 15
NS 20
1790
2600
3370
Torque Nm
4.5 ±0.5
7
4.5 ±0.5
3
10
Spanner socket 13 mm
8-10
Spanner socket 13 mm
8-10
Spanner socket 13 mm
5.5 ±0.5
Spanner socket 13 mm
NS 25
NS 30
3700
4370
Spanner size
T30
T50
T30
ISK 10 mm
010-916_SON_EN

Advertisement

Table of Contents
loading

Table of Contents