SPX FLOW APV DELTA DKR2 Instruction Manual page 20

Dn25-100 1"-4" double seat ball valve, safety against explosion - for specific atex-applications
Table of Contents

Advertisement

APV
APV_DKR2 ATEX_UK-0_022018.indd
15
11. Maintenance
Additionally required maintenance for applications in ATEX
environment
Replacement of spring for potential equalization if damaged.
DKR2 Valve actuated version
Valve maintenance for
actuator with spring
Functional test,
visual inspection of actuator
movement (turning angle) and
control of abnormal running
noise of spring
Change interval of actuator
(turning actuator)
*complies with about 8 years in 1-shift-operation and 10-15 cycles per hour.
Note
1 x per year
In case of damage,
incomplete actuator movement
(turning angle), considerable
running noise of spring as well as
after 250,000 cycles* as
preventive measure, however,
after 10 years at the latest.
Double Seat Ball Valve DELTA DKR2
Instruction Manual: UK-0
UK
ATEX Design

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the APV DELTA DKR2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents