Altendorf WA 80 Operator's Manual page 41

Hide thumbs Also See for WA 80:
Table of Contents

Advertisement

Saw blade with stepless cut width RAPIDO
Replace scorer saw blades for RAPIDO
Take the adjuster unit off the machine; the clamping
screw may have to be released since a tightened
clamping screw can cause the adjuster unit to jam
on the shaft!
Dismantling:
With hexagonal key:
Release clamping screw (1) appr. 3-4 turns, ro-
tate spindle (2) clockwise until the flange (3)
can be pulled away from holder (4)
With Innentorx key:
Unscrew screws (5)
Remove circular saw blade (6)
Fully clean flange (3) and screws (5). The run-
ning and flange surfaces must be clean and
dust free.
Fit a new circular saw blade, note direction of
rotation and arbor image when fitting: The cir-
cular saw blade (6) lies flat on the flange (3) and
the protrusion on the circular saw blade points
to the contact surface
Screw in screws (5) and tighten to a torque of
8,6Nm
Proceed in the same way with the other half of
the adjuster unit
© ALTENDORF 2007
Assembly:
Do not oil or grease!
Clamping screw (1) is released
Fit the flange (3) vertically on to the holder (4)
so that the spindle (2) engages in the threaded
hole (7)
Use the hexagonal key to turn the spindle (2) in
a counterclockwise direction. The flange (3) will
be pulled into the holder (4) no additional force
may be used here
Continue to turn spindle (2) until the two halves
of the circular saw blade are lying against each
other
Install the adjuster unit on the machine
Setting the cutting width, see above
Only turn clamping screw (1) slightly
38

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Altendorf WA 80