SMA Solar Technology AG
Communication Connection
Type of terminal
Cable cross-section
Cable gland
Sealing range
Cable type
Number of shield clamps
Maximum shield diameter
Remote Tripping with Shunt Release
Nominal voltage
Extended operating range
Nominal frequency
Power consumption
Remote Tripping with Undervoltage Release
Nominal voltage
Extended operating range
Nominal frequency
Power consumption
Feedback contact with Remote Tripping
Nominal voltage
Nominal current
Format
Interfaces
Communication
Transmission rate
Monitored overvoltage protectors type II
String current measurement
Technical Description
4-conductor through terminal
2
0.08 mm
... 2.5 mm
M25
8 mm ... 17 mm
4 x 2 x 0.5 mm Li2YCYv (TP)
2
8 mm
220 V
... 240 V
AC
‒30 % ... +10 %
50 Hz / 60 Hz
100 VA
220 V
... 240 V
AC
‒15 % ... +10 %
50 Hz / 60 Hz
3 VA
250 V
AC/DC
5 A
/ 0.15 A
AC
DC
1 x toggle switch
RS485
19200 Baud
Yes
Yes
SSM-TEN103132