SMA Solar Technology AG
8.4.3 Setting the groups
1. Sunny String-Monitor in the system tree.
2. In the "Parameters" area, click Group channel for the desired channel, or Group all chan.
3. In the area "Channel value", enter the number the group per channel of for all channels.
4. To save, select [Set].
8.4.4 Setting the Time Window
1. Sunny String-Monitor in the system tree.
2. In the area "Parameter", Monitoring (X) On for the desired channel or Monitoring. On for
the complete Sunny String-Monitor.
3. In the area "Channel value" enter the desired time of day starting at which the measuring
channel or the Sunny String-Monitor should be monitored.
4. To save, select [Set].
5. In the area "Parameter", Monitoring (X) Off for the desired channel or Monitoring Off for
the complete Sunny String-Monitor.
6. In the area "Channel value" enter the desired time of day up to which the measuring channel or
the Sunny String-Monitor should be monitored.
7. To save, select [Set].
8.4.5 Setting the Tripping Time
1. Click on the device label at the second level in the system tree.
2. In the area "Parameter", click on SMU_Error Report Time.
3. In the area "Channel value" enter the desired value in minutes.
4. To save, select [Set].
8.4.6 Setting the Tolerance
1. Click on the device label at the second level in the system tree.
2. In the "Parameter" area click SMU_Tolerance Grp for the desired group.
3. In the area "Channel value" enter the desired value in percent.
4. To save, select [Set].
Technical Description
8 Function of the String Current Monitoring
SSM-TEN103132
55