Parameter list VLT 8000 AQUA
PNU
Parameter
#
description
300
Terminal 16 Digital input
301
Terminal 17 Digital input
302
Terminal 18 Digital input
303
Terminal 19 Digital input
304
Terminal 27 Digital input
305
Terminal 29 Digital input
306
Terminal 32 Digital input
307
Terminal 33 Digital input
308
Terminal 53, analog
input voltage
309
Terminal 53, min. scaling
310
Terminal 53, max. scaling
311
Terminal 54, analog
input voltage
312
Terminal 54, min. scaling
313
Terminal 54, max. scaling
314
Terminal 60, analog input
current
315
Terminal 60, min. scaling
316
Terminal 60, max. scaling
317
Time out
318
Function after time out
319
Terminal 42, output
320
Terminal 42, output,
pulse scaling
321
Terminal 45, output
322
Terminal 45, output,
pulse scaling
323
Relay 1, output function
324
Relay 01, ON delay
325
Relay 01, OFF delay
326
Relay 2, output function
327
Pulse reference,
max. frequency
328
Pulse feedback, max. frequency
Changes during operation:
"Yes" means that the parameter can be changed,
while the VLT AFD is in operation. "No" means that
the VLT AFD must be stopped before a change can
be made.
4-Setup:
"Yes" means that the parameter can be programmed
individually in each of the four setups, i.e. the same
parameter can have four different data values. "No"
means that the data value will be the same in all four
setups.
Conversion index:
This number refers to a conversion figure to be used
when writing or reading to or from a VLT AFD by
means of serial communication.
MG.90.D1.02
– VLT is a registered Danfoss trademark
VLT
®
5000/5000 Flux/6000 HVAC/8000 AQUA PROFIBUS
Factory setting
Reset
No operation
Start
Reversing
Coasting stop, inverse
Jog
No operation
No operation
No operation
0.0 V
10.0 V
No operation
0.0 V
10.0 V
Reference
4.0 mA
20.0 mA
10 sec.
Off
⇒ 4-20 mA
0 - I
MAX
5000 Hz
⇒ 0-20 mA
0 - f
MAX
5000 Hz
No alarm
0.00 sec.
2.00 sec.
Running
5000 Hz
25000 Hz
Range
Changes 4-Setup
during operation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.0 - 10.0 V
Yes
Yes
0.0 - 10.0 V
Yes
Yes
Yes
Yes
0.0 - 10.0 V
Yes
Yes
0.0 - 10.0 V
Yes
Yes
Yes
Yes
0.0 - 20.0 mA
Yes
Yes
0.0 - 20.0 mA
Yes
Yes
1 - 99 sec.
Yes
Yes
Yes
Yes
Yes
Yes
1 - 32000 Hz
Yes
Yes
Yes
Yes
1 - 32000 Hz
Yes
Yes
Yes
Yes
0 - 600 sec.
Yes
Yes
0 - 600 sec.
Yes
Yes
Yes
Yes
Depends on
Yes
Yes
input terminal
0 - 65000 Hz
Yes
Yes
Conversion index
7 4
2
1
0
- 1
- 2
- 3
- 4
Data type:
Data type shows the type and length of the telegram.
Data type
Description
3
Integer 16
4
Integer 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Text string
Data
Conversion
type
index
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
-1
5
-1
5
0
5
-1
5
-1
5
0
5
-4
5
-4
5
0
5
0
5
0
6
0
5
0
6
0
5
0
6
0
6
0
5
0
6
0
6
0
Conversion factor
0.1
100
1 0
1
0.1
0.01
0.001
0.0001
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt 50006000 hvac8000 aqua profibusVlt 5000 series