Parameter list VLT 8000 AQUA
PNU
Parameter
#
description
200
Output frequency range
201
Output frequency low limit, f
202
Output frequency high limit, f
203
Reference site
204
Minimum reference, Ref
205
Maximum reference, Ref
206
Ramp-up time
207
Ramp-down time
208
Automatic ramp-up/down
209
Jog frequency
210
Reference type
211
Preset reference 1
212
Preset reference 2
213
Preset reference 3
214
Preset reference 4
215
Current limit, I
LIM
216
Frequency bypass, bandwidth
217
Frequency bypass 1
218
Frequency bypass 2
219
Frequency bypass 3
220
Frequency bypass 4
221
Warning: Low current, I
222
Warning: High current, I
223
Warning: Low frequency, f
224
Warning: High frequency, f
225
Warning: Low reference, Ref
226
Warning: High reference, Ref
227
Warning: Low feedback, FB
228
Warning: High feedback, FB
1) Sum = Global
2) Preset reference = North America
Changes during operation:
"Yes" means that the parameter can be
changed, while the VLT AFD is in operation. "No"
means that the VLT AFD must be stopped before
a change can be made.
4-Setup:
"Yes" means that the parameter can be
programmed individually in each of the four
setups, i.e. the same parameter can have four
different data values. "No" means that the data
value will be the same in all four setups.
Conversion index:
This number refers to a conversion figure to be
used when writing or reading to or from a VLT
AFD by means of serial communication.
52
VLT
®
5000/5000 Flux/6000 HVAC/8000 AQUA PROFIBUS
Factory setting
0 -120 Hz
0.0 Hz
MIN
60 Hz
MAX
Hand/Auto linked reference
0.000
MIN
60 Hz
MAX
Depends on the unit
Depends on the unit
Enable
10.0 Hz
Sum
1)
/Preset reference
0.00 %
0.00 %
0.00 %
0.00 %
1.0 x I
[A]
VLT,N
0 Hz
120 Hz
120 Hz
120 Hz
120 Hz
0.0 A
LOW
I
HIGH
VL T,MAX
0.0 Hz
LOW
120.0 Hz
HIGH
999,999.999
LOW
999,999.999
HIGH
999,999.999
LOW
999,999.999
HIGH
Range
Changes 4-Setup
during operation
0 - 1000 Hz
No
0.0 - f
Yes
MAX
f
- par. 200
Yes
MIN
Yes
0.000-par. 100
Yes
par. 100-999.999,999 Yes
1 - 3600
Yes
1 - 3600
Yes
Yes
0.0 - par. 100
Yes
2)
Yes
-100.00 - 100.00 %
Yes
-100.00 - 100.00 %
Yes
-100.00 - 100.00 %
Yes
-100,00 - 100,00 %
Yes
0,1-1,1 x I
[A]
Yes
VLT,N
0 - 100 Hz
Yes
0.0 - par. 200
Yes
0.0 - par. 200
Yes
0.0 - par. 200
Yes
0.0 - par. 200
Yes
0.0 - par. 222
Yes
Par. 221 - I
Yes
VLT,MAX
0.0 - par. 224
Yes
Par. 223 - par. 200/202 Yes
-999,999.999 - par. 226 Yes
Par. 225 - 999,999.999 Yes
-999,999.999 - par. 228 Yes
Par. 227 - 999,999.999 Yes
Conversion index
74
2
1
0
-1
-2
-3
-4
Data type:
Data type shows the type and length of the telegram.
Data type
Description
3
4
5
6
7
9
MG.90.D1.02
– VLT is a registered Danfoss trademark
Data
Conversion
type
index
0
5
Yes
-1
6
Yes
-1
6
Yes
0
5
Yes
-3
4
Yes
-3
4
Yes
0
7
Yes
0
7
Yes
0
5
Yes
-1
6
Yes
0
5
Yes
-2
3
Yes
-2
3
Yes
-2
3
Yes
-2
3
Yes
-1
6
Yes
0
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-1
6
Yes
-3
4
Yes
-3
4
Yes
-3
4
Yes
-3
4
Yes
Conversion factor
0.1
100
10
1
0.1
0.01
0.001
0.0001
Integer 16
Integer 32
Unsigned 8
Unsigned 16
Unsigned 32
Text string

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt 50006000 hvac8000 aqua profibusVlt 5000 series

Table of Contents