Parameter list
VLT 5000 Flux
PNU Parameter
#
description
001 Language
002 Local/remote control
003 Local reference
004 Active setup
005 Programming setup
006 Copying of setups
007 LCP copy
008 Display scaling speed
009 Display line 2
010 Display line 1.1
011
Display line 1.2
012 Display line 1.3
013 Local operation mode
014 Local stop
015 Local jog
016 Local reversing
017
Local reset of trip
018 Lock for data change
019 Operating state at
power-up, local control
024 Userdefined Quick Menu
025 Quick Menu Setup
100 Configuration
101 Torque characteristics
102 Motor power
103 Motor voltage
104 Motor frequency
105 Motor current
106 Rated motor speed
107 Automatic motor adaptation, AMA
119 High starting torque
120 Start delay
121 Start function
122 Function at stop
123 Min. speed for activating
function at stop
124 DC holding current
125 DC braking current
126 DC braking time
127 DC brake cut-in frequency
128 Motor thermal protection
129 External motor fan
130 Start speed
131 Initial current
150 Stator resistance
151 Rotor resistance
152 Stator leakage reactance
153 Rotor leakage reactance
154 Main reactance
156 Pole number
158 Ironloss resistance
161 Minimum inertia
162 Maximum inertia
MG.90.D1.02
– VLT is a registered Danfoss trademark
VLT
®
5000/5000 Flux/6000 HVAC/8000 AQUA PROFIBUS
Factory setting
English
Remote control
000.000
Setup 1
Active setup
No copying
No copying
1
Speed [Rpm]
Reference [%]
Motor current [A]
Power [kW]
LCP control
Enable
Not possible
Not possible
Possible
Not locked
Forced stop, use saved ref.
Not active
000
Speed control, closed loop
High - constant torque
Depends on the unit
Depends on the unit
50 Hz
Depends on the unit
Depends on the unit
Adaptation off
0.0 sec.
0.0 sec.
Coasting in start delay time
Coasting
0.0 rpm
50 %
50 %
10.0 sec.
Off
No protection
No
0.0 rpm
0.0 Amp
Depends on unit
Depends on unit
Depends on unit
Depends on unit
Depends on unit
4-pole motor
10000Ω
Depends on unit
Depends on unit
Range
Changes
during
operation
Yes
No
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
No
0.01 - 100.00
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
0-999
Yes
No
No
Yes
Yes
Yes
0.18-500 kW
No
Yes
200 - 575 V
No
Yes
No
Yes
0.01- I
No
Yes
VLT;MAX
100-60000 rpm
No
Yes
No
No
0.0 - 0.5 s
Yes
Yes
0.0 - 10.0 s
Yes
Yes
Yes
Yes
Yes
Yes
0 - 600 rpm
Yes
Yes
0 - 100 %
Yes
Yes
0 - 160 %
Yes
Yes
0.0 - 60.0 sec.
Yes
Yes
0.0-par. 202
Yes
Yes
Yes
Yes
Yes
Yes
0.0-600 rpm
Yes
Yes
0.0-par. 105
Yes
Yes
Ohm
No
Yes
Ohm
No
Yes
Ohm
No
Yes
Ohm
No
Yes
Ohm
No
Yes
2-100
No
Yes
1-10000Ω
No
Yes
Kgm
2
No
Yes
Kgm
2
No
Yes
Conversion
Index
0
5
0
5
-3
4
0
5
0
5
0
5
0
5
-2
6
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
6
0
5
0
5
1
6
0
6
0
6
-2
7
0
6
0
5
-1
5
-1
5
0
5
0
5
-1
5
0
6
0
6
-1
6
-1
6
0
5
0
5
-1
5
-1
6
-4
7
-4
7
-3
7
-3
7
-3
7
0
5
0
6
-4
7
-4
7
39