Value
0 — 127
255 — 128
Te m pe rature Scale (Param e te r Num be r 2, Param e te r Size 1)
Sensor will report temperature in this scale
Value
0 — 127
255 — 128
D e lta T (Param e te r Num be r 3, Param e te r Size 1)
defines the temperature steps of the heating control value is 0.1 K
Value
0 — 100

Command Classes

Supported Command Classes
Basic (version 0)
Thermostat Mode (version 1)
Thermostat Setpoint (version 1)
Wake Up (version 2)
Binary Switch (version 1)
Version (version 1)
Battery (version 1)
Configuration (version 1)
Multilevel Sensor (version 1)
Manufacturer Specific (version 1)
Association (version 1)

Technical Data

Disable (Default 0)
Enabled
Celsius (Default 0)
Fahrenheit
Kelvin (Default 10)
D e scription