4.2 Installation Standards

4.2 Installation Standards
The SERVOPACK must be installed in a fully enclosed metal control panel. Observe the standards
for mounting SERVOPACKs in control panels, including those for the mounting SERVOPACKs side
by side in one control panel as shown in the following illustration.
• SERVOPACK Mounting Orientation
Mount the SERVOPACK vertically to the wall, with the front panel (the side with the panel operator
display) facing out.
• Cooling
Refer to the following diagram and leave sufficient space for cooling by fans and natural convection.
• Mounting SERVOPACKs Side by Side in a Control Panel
30 mm or more
Leave sufficient space on each side and at the top and the bottom of each SERVOPACK. The
width on each side varies in accordance with the models of the SERVOPACKs used.
SERVOPACK Model SGDV-
R70F, R90F, 2R1F, R70A, R90A, 1R6A, 2R8A
2R8F, 3R8A, 5R5A, 7R6A
120A, 180A, 200A, 330A, 470A, 550A, 590A, 780A,
1R9D, 3R5D, 5R4D, 8R4D, 120D, 170D, 210D, 260D,
280D, 370D
Also install cooling fans above the SERVOPACKs to disperse local pockets of warmer air around
the SERVOPACKs.
• Inside the Control Panel
The conditions inside the control panel should be the same as the environmental conditions of
the SERVOPACK. Refer to the environmental conditions in 2.1 General Specifications
• During Operation
Do not touch the connectors or IO cables during operation if the panel door is open.
12
Fan
Width varies with
SERVOPACK model
.
.
Fan
40 mm or more
40 mm or more
Side
Left
1 mm or more
1 mm or more 10 mm or more
10 mm or more
Top and bottom
Right
40 mm or more