Prerequisites
To obtain the highest possible measurement accuracy and to avoid damage
to equipment:
Ensure the brackets fit solidly onto their mounting surfaces.
Do not use self-constructed mounting brackets, or modify the original
bracket configuration. For example, do not use support posts longer than
those supplied with the bracket.
Choose the shortest support posts that will allow the laser beam to pass
over or through the coupling.
Note
Refer to
Figure 2-1
The numbers in the figure correspond to the numbers in the following steps.
Figure 2-1:
Procedure
1. Insert the support posts into the bracket.
2. Fasten the support posts in place by tightening the hex screws on the
sides of the bracket frame.
3. Place the bracket on the shaft or coupling, wrap the chain around the
shaft and feed it through the other side of the bracket. If the shaft is
smaller than the width of the bracket frame, insert the chain from the
inside of the bracket. If the shaft is larger than the bracket width, insert
the chain into the frame from the outside.
4. Catch the chain loosely on the anchor peg.
5. Turn the bracket thumbscrew clockwise to tighten the assembly onto the
shaft.
Quick Start Guide
for detailed illustrations on how to mount the brackets.
Mount the brackets
Quick Start Guide
11