Download Print this page

Emerson AMS 2140 Quick Start Manual page 14

Machinery health analyzer advanced laser alignment application
Hide thumbs Also See for AMS 2140:

Advertisement

Quick Start Guide
a. If the laser beam adjustment LEDs on the sensor are blinking green
twice every second, the angle at which the laser beam enters the
sensor is correct, but an offset is present. Eliminate the offset by
sliding back the sensor dust cap to cover the lens, then loosen the
chain type bracket supporting sensor, and move the sensor sideways.
At the same time, release the sensor clamping levers and move the
sensor upwards and downwards until the laser beam is centered on
the dust cap.
During this adjustment, do not touch the laser.
b. Slide the sensor dust cap to open the lens and check the blinking of
the four laser beam adjustment LEDs. If all four are blinking green
once every second, then the laser beam is correctly centered on the
sensor.
Refer to the Alignment chapter of the AMS 2140 Machinery Health
Analyzer User Guide for more information on the laser beam
adjustment LED lights and their meanings.
2.5
Enable Bluetooth radio in the AMS 2140
1. Press Home > F5 Comm Setup > F7 Bluetooth Setup.
2. Press F2 Bluetooth to enable the Bluetooth radio.
When the radio is enabled, the
the screen.
2.6
Pair the sensor
For the laser fixtures to communicate with the AMS 2140, you must first pair
the sensor. Bluetooth radio is integrated into the sensor.
Prerequisites
Ensure the sensor is close to the AMS 2140 (within 30 feet) and is turned
on.
Enable the Bluetooth radio in your AMS 2140.
Procedure
1. Press Home > F5 Comm Setup > F7 Bluetooth Setup.
14
CAUTION!
icon appears in the upper corner of
AMS 2140 Advanced Laser Alignment Application
December 2018

Hide quick links:

Advertisement

loading