IMPORTANT -
Code table
Special feature: Temporary codes
The values written in the codes C2500 and C2501 will be deleted after the device is switched off.
Temporary codes are suitable for those parameters to which access is made during one switch-on
period only.
It is possible to access the flag area of the PLC directly (e.g. via HMI) using codes C2500/2501
without applying a variable.
Code
LCD
Possible settings
Lenze
Choice
C2500
-
-
%MW 0 ... 254
1
...
255
C2501
-
-
%MW255 ... 509
1
...
255
How to read the code table:
Meaning
Code C0039
1
Subcode 1 of code C0039
2
Subcode 2 of code C0039
0
Subcode 14 of code C0039
Subcode 15 of code C0039
Parameter value of the code can only be modified when the controller is inhibited
Keypad LCD
Factory setting of the code
Display code
•
Display possible only
The column "Important" contains further information
{1 %}
99 Minimum value
Additional, important explanation of the code
9300 Servo PLC
{smallest step/unit}
9300ServoPLC EN 1.4
Appendix
IMPORTANT
The data of these codes
•
are not saved in the EEPROM of the device
•
cannot be saved with C0003 = 1 in the
parameter set of the device
•
will be lost after mains disconnection or
ill b l t ft
i
mains failure
•
are linked with the flag area of the PLC
maximum value