Code Table - Lenze 8200 Operating Instructions Manual

8200 motec frequency inverter 0.25 kw ... 7.5 kw
Hide thumbs Also See for 8200:
Table of Contents

Advertisement

Appendix

Code table

14.6
Code table
How to read the code table
Column
Abbreviation
Code
Cxxxx
*
v
s
(A)
uSEr
Name
Lenze
à
Selection
1
IMPORTANT
Code
Possible settings
No.
Name
Lenze
C0001
Selection of
v
setpoint entry
(operating mode)
14−10
Meaning
Code Cxxxx
1
Subcode 1 of Cxxxx
2
Subcode 2 of Cxxxx
Parameter value of the code is the same in all parameter sets
Keypad E82ZBC
Keypad XT EMZ9371BC
Keypad E82ZBC
Keypad XT EMZ9371BC
Code, subcode or selection are only available when using an Application−I/O
With Lenze setting the code is available in the USER−menu
Name of the code
Lenze setting (value at delivery or after restoring the delivery state with C0002)
Further information can be obtained from "IMPORTANT"
Min. value
{%}
99
Brief, important explanations
Selection
0
0
Setpoint entry via AIN1 (X3/8 or X3/1U, X3/1I)
1
Setpoint entry via keypad or parameter channel
of an AIF bus module
2
Setpoint selection via AIN1 (X3/8 or X3/1U, X3/1I)
3
Setpoint selection via process channel of an AIF
bus module
EDB82MV752 EN 5.2
·
The parameter value of a code can be different in every parameter
set.
·
Parameter value accepted immediately (ONLINE)
Changed parameters will be accepted after pressing
Changed parameters will be accepted after pressing
Changed parameters will be accepted after pressing
controller is inhibited
Changed parameters will be accepted after pressing
the controller is inhibited
{unit}
Max. value
IMPORTANT
·
Changing C0001 will cause the changes
mentioned below under C0412 and
C0410, if no free configuration under
C0412 was made before.
·
In the event that a free configuration
was made under C0412 (verification =
C0005 = 255), C0001 does not
influence C0412 and C0410. The signals
must be linked manually.
·
Free configuration under C0412 or
C0410 does not change C0001!
·
The control can be realised via terminals
or PC/keypad
·
C0412/1 and C0412/2 are linked with
the analog input 1(C0412/1 = 1,
C0412/2 = 1).
·
C0410 is not changed.
·
Under C0412 the linkage with the
analog input is separated (C0412/1 =
255, C0412/2 = 255).
·
Setpoint selection via C0044 or C0046.
·
C0410 is not changed.
·
C0412/1 and C0412/2 are linked with
the analog input 1 (C0412/1 = 1,
C0412/2 = 1)
·
C0410 is not changed.
·
C0001 = 3 must be set to select a
setpoint via a process data channel of
an AIF bus module (types 210x, 211x,
213x, 217x)! Otherwise the process data
will not be evaluated.
·
C0412/1 and C0412/2 are linked with
the analog input words AIF−IN.W1 and
AIF−IN.W2 (C0412/1 = 10, C0412/2 =
11).
·
C0410/1 ... C0410/16 are linked with
the single bit of the AIF control word
(AIF−CTRL) (C0410/1 = 10 ...
C0410/16 = 25)
v
T V
v
if the
T V
if
^ 7−32
L

Advertisement

Table of Contents
loading

Table of Contents