Selection
Selection

5 .4 Burner head

5 .4 .1 Use

The burner ECOMAX can be equipped with 2 different
burner heads. Stage combustion is standard. For some
burner variants, a menox version is also possible, which
allows for switchover to menox
flameless combustion when the furnace temperature
exceeds 850°C in a direct heating system.
Use
Standard flame mode
®
menox
low NO
mode
1)
X
1)
menox
®
low NO
mode on request.
X

5 .4 .2 Gas type

Gas type
Natural gas L and H quality
Propane, propane/butane, butane
Coke oven gas, town gas
Low calorific value gas
1)
Calorific value range < 1.7 on request.
2)
Calorific value ranges in kWh/m
lower calorific value H
.
u
3)
Calorific value ranges in BTU/SCF refer to the
upper calorific value H
o
ECOMAX · Edition 10.17
®
low NO
mode with
X
Burner head code letter
S
M
Code letter
B
G
D
L
3
refer to the
.
Calorific value range
kWh/m
3
(n)
2)
BTU/scf
3)
8 – 12
810 – 1215
25 – 35
2560 – 3474
4 – 5
421 – 503
1.7
1)
 – 3
161 – 290
Density ρ
kg/m
3
(n)
lb/scf
0.7 – 0.9
0.041 – 0.053
2.0 – 2.7
0.118 – 0.159
0.4 – 0.6
0.024 – 0.035
0.9 – 1.15
0.053 – 0.068
21