1 .4 .2 Air/gas ratio control

If the system does not include flow rate control, tem-
perature-dependent pressure losses in the burner are
not compensated for. The air index lambda drops with
increasing furnace temperature (increasing air preheat-
ing). Therefore, in a cold furnace, an increased lambda
value is to be set to ensure sufficient excess air, even
when the furnace temperature is at its maximum. A fur-
nace at 1100°C with λ = 1.1 (approx. 2% O
burner setting of approx. 4% O
furnace is cold.