7 .12 Condition on delivery

The position of the gas, air and flue gas connections
can be customized depending on how the burner is to
be installed on the furnace. The positions of the con-
nections are coded using the numbers 0, 3, 6 and 9.
Code
0
3
6
9
The codes relating to the positions of the connections
are specified in the following order: flue gas – air – gas –
and cooling air (increased furnace cooling) if required.
Provided that there are no specifications, the burners
are supplied as follows:
ECOMAX../R for indirect heating with connector posi-
tion 066, i.e. with flue gas connection at the top and
gas and air connection at the bottom.
9
ECOMAX · Edition 10.17
Connection position
top
right-hand side
bottom
left-hand side
0
3
6
Add-on components with the marking /E, such as the
air flow detector set, UV adapter, purge air nozzle, etc,
are installed on the burner at the factory, provided that
they are ordered at the same time as the burner.
7 .13 Increased furnace cooling with
ECOMAX . .K
L1, N, PE
DI
PLC
DI
P
A
32
6
3
5
23
22
µC
33
12
26
VG..L
VG
GEH
EKO
VR..N
Depending on the technical requirements for the pro-
cess, cooling can be implemented in two stages.
P
4
19
18
17
16
BCU 465..C
60