Emissions; Build Up Of Noise - Honeywell Ecomax Series Technical Information

Self-recuperative burner for gas
Table of Contents

Advertisement

Project planning information for direct heating

6 .14 Emissions

CO and NO
values depend on the furnace tempera-
X
ture, air preheat temperature, burner type and burner
settings (NO
values on request).
X
If operated with LPG, NO
higher.
600
500
400
300
200
100
0
600
700
800
Flue gas temperature at recuperator inlet [°C]
NO
values in the diagram apply to natural gas.
X
ECOMAX · Edition 10.17
values are approx. 25%
X
900
1000
1100
1200

6 .15 Build up of noise

The sound level of a naked flame may be significantly
more than 90 dB(A) due to the high flame velocity. In
the case of fitted burners, the sound level of the single
burner which can be measured outside the furnace is
usually between 75 and 82 dB(A).
In a furnace system, the value which can be measured
depends on the capacity, excess air volume, flue gas
extraction and flue gas temperature of the single burn-
ers as well as the burner arrangement and ambient
influences.
1300
46