Selection
5 .6 Connection for additional furnace
cooling
The air volume supplied to the burner in cooling mode
can be increased using an optional intermediate flange
with an additional cooling air connection on the burner
ECOMAX.
The air supplied via the additional air connection flows
in the centre of the burner inside the air guide tube. The
air volume is twice the standard combustion air volume.
ECOMAX · Edition 10.17

5 . 7 Electrode made of Kanthal APM

Burners ECOMAX..M and ECOMAX..P can be equipped
with a bend-resistant electrode made of Kanthal APM
as an option. This is recommend for direct heating
as of 1050°C and indirect heating as of 950°C, see
page 38 (Flame control).
On ECOMAX..C, the Kanthal electrode is standard.
23