Project planning information for direct heating
6 .5 .4 Furnace temperature measurement
Measurement of the furnace temperature must be
representative for the flue gas temperature in the ex-
traction zone on the burner. If measurement is not rep-
resentative, this will involve a risk of overheating of the
recuperator head.
6 .5 .5 Heat guard
During operation, the burner body and eductor or flue
gas connector can reach surface temperatures of
over 80°C. Do not insulate the burner, eductor and flue
gas connector to prevent material overheating.
We recommend that warning signs and a contact guard
be fitted, for example made of perforated sheet metal.