Low Temperature Burners
High turndown
Available in 4 sizes
Capacities 2 kW - 558 kW (HHV)
Stable and clean combustion
Suitable for UV scanner and flame rod
Low gas pressure requirements
Ease of installation and operation with low
maintenance requirements
All metal construction
Multi voltage and frequency blower motors
Better control on CO over the entire turndown of the
burner
Pilot connection availability
Easily Switch between Natural Gas and Propane
TECHNICAL CATALOG

PRODUCT DESCRIPTION

The VALUPAK®-II is designed for process air heating
A motorized gas control valve controls the heat output of
the burner over the full operating range. The gas flows
through the nozzle and then along the inside of the burner
cone where combustion air is progressively and
tangentially mixed with the gas. This results in a short, very
stable flame and clean combustion.
Like many other Honeywell products, the standard
VALUPAK-II burner can be customized into a package
which could include a gear motor, burner controls,
automatic shut-off valves, flame sensors and/or pressure
switches.
32-00188-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell MAXON VALUPAK-II Series

  • Page 1: Product Description

    This results in a short, very • Ease of installation and operation with low stable flame and clean combustion. maintenance requirements Like many other Honeywell products, the standard • All metal construction VALUPAK-II burner can be customized into a package •...
  • Page 2 VALUPAK®-II AVAILABLE VALUPAK®-II SIZES Capacity and selection data in kW, 50 Hz operation Gross heating value = 10.9 kWh/m (st), d = 0.6 All figures are for balanced - 0 mbar - duct pressure VALUPAK®-II size U/HC Standard blower type Maximum heat release kW (HHV) Minimum heat release...
  • Page 3 VALUPAK®-II DIMENSIONS - VALUPAK®-II 60 N[2] Plug (Alternative SI position) 4 x Ø12 DIMENSIONS AND WEIGHTS ØO E[1] ØP 4 x 90° Rc1/4" Rp 1/2" Gas Inlet 1/2" NPT Flame Rod VP-II 60 Dimensions in mm unless stated otherwise Blower ØF ØO ØP...
  • Page 4 VALUPAK®-II DIMENSIONS - VALUPAK®-II 150, 300 & 600 1/4" NPT Air switch connection AIR-GAS linkage 1/8" Gas pressure test connection Sight Spark ignitor 1/8" Combustion air glas 1/2" NPT pressure test connection 1/2" NPT flame supervision connection see note R[2] Gasinlet 1"...
  • Page 5 VALUPAK®-II APPLICATIONS Options • round air filter Specifically designed for applications where burners are • single phase motor for sizes 60, 150 and 300 used under balanced pressure conditions such as in textile • long discharge sleeve 300 mm machines, printing machines and many other types of •...
  • Page 6 VALUPAK®-II SPECIFICATIONS OF VALUPAK®-II BURNERS FOR 50 HZ OPERATION Capacity data in kW Gross heating value = 10.9 kWh/m (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK®-II size U/HC Standard blower type Maximum heat release kW(Hs) Minimum heat release...
  • Page 7: Burner Mounting

    VALUPAK®-II INSTALLATION AND OPERATING They must be rechecked after start-up and loosened if necessary to prevent deformation of cone. See start-up INSTRUCTIONS instruction for details. Installation instructions Tightening can lead to cone distortion and greatly reduced cone and discharge sleeve life. Instructions provided by the company or individual Discharge sleeve must be flush with, or extended beyond responsible for the manufacture and/or overall installation...
  • Page 8 VALUPAK®-II Installation of flame scanner Instead of a flame rod, a flame scanner can be applied to a VALUPAK®-II burner (with exception of VALUPAK®-II 60) without any modification. 1) Stiffener plate 2) Lock screw 3) Discharge sleeve 4) Viewing port 5) Additional burner support 6) Stud bolt...
  • Page 9 VALUPAK®-II Flame rod or UV scanner arrangement with spark ignitor Sizes VP-II 60 - VP-II 600 Spark ignitor Flame rod arrangement Spark ignitor 1/2" NPT Detail B Dimensions in mm, unless stated otherwise Spark ignitor Flame rod Model VALUPAK®-II VP-II 60/UHC 102 VP-II 60/UHC 122 VP-II 60/UMI 300 VP-II 150...
  • Page 10: Operating Instructions

    VALUPAK®-II Operating instructions START-UP AND ADJUSTMENT INSTRUCTIONS FOR VALUPAK®-II The operating instructions below are provided only as a BURNERS guideline and are not intended to replace those provided by the manufacturer of a complete system of which the VALUPAK®-II burner is only a part. Where applicable, Instructions provided by the company or individual instructions provided by the system's manufacturer shall responsible for the manufacture and/or overall installation...
  • Page 11 VALUPAK®-II 6. Check the adjustments of the flame rod, spark ignitor and/or pilot (See page 9 and the wiring). 7. Start all machine air blowers. Start burner with its start-stop switch. Motor of combustion air fan will be started shortly after, by means of the burner flame safeguard programming relay.
  • Page 12 VALUPAK®-II For More Information For More Information The Honeywell Thermal Solutions family of products includes The Honeywell Thermal Solutions family of products includes Honeywell Combustion Safety, Eclipse, Exothermics, Hauck, Honeywell Combustion Safety, Eclipse, Exothermics, Hauck, Kromschröder and Maxon. To learn more about our products, Kromschröder and Maxon.