Project planning information for direct heating
6 .5 Installation
6 .5 .1 Installation position
90°
The burner ECOMAX can be installed in any position
between 0° (horizontal) and 90° (vertical from top to
bottom). The ECOMAX may be oriented upwards at an
angle of max. 15° from the horizontal.
Eductor EJEK installation position:
vertical, max. angle 10°.
If the burner is installed at an angle of more than 10°
from the vertical or horizontal, a special version of flue
gas eductor EJEK is required. This is available on re-
quest.
ECOMAX · Edition 10.17
6 .5 .2 Tangential or angled burner installation
If the burner is installed tangentially or at an angle, an
opening should be provided in the furnace lining to
15°
ensure unobstructed flue gas extraction. The choice of
furnace lining in this area should take account of the
0°
burner's very high outlet velocity. In addition, reflection
from the furnace wall to the burner must be considered.
1,5 x B
B
35