Project planning information for direct heating

6 .5 Installation

6 .5 .1 Installation position

90°
The burner ECOMAX can be installed in any position
between 0° (horizontal) and 90° (vertical from top to
bottom). The ECOMAX may be oriented upwards at an
angle of max. 15° from the horizontal.
Eductor EJEK installation position:
vertical, max. angle 10°.
If the burner is installed at an angle of more than 10°
from the vertical or horizontal, a special version of flue
gas eductor EJEK is required. This is available on re-
quest.
ECOMAX · Edition 10.17

6 .5 .2 Tangential or angled burner installation

If the burner is installed tangentially or at an angle, an
opening should be provided in the furnace lining to
15°
ensure unobstructed flue gas extraction. The choice of
furnace lining in this area should take account of the
burner's very high outlet velocity. In addition, reflection
from the furnace wall to the burner must be considered.
1,5 x B