Download Print this page

Honeywell Q314 Product Data

Pilot burners
Hide thumbs Also See for Q314:

Advertisement

Q314, Q324, Q327, Q350, Q377, Q379, Q380
Q324
Q327
Q382
Q379

APPLICATION

These pilot burners provide main burner ignition for natural
and LP gas-fired equipment. Used with a 30 mV thermopile
and/or thermocouple (depending on model) to provide
automatic pilot safety control.
® U.S. Registered Trademark
Copyright © 1997 Honeywell Inc. • All Rights Reserved
Q350
Q314
Q380
Q377
and Q382 Pilot Burners

FEATURES

• Q324 and Q327 are primary aerated, spud orifice pilot
burners.
• Q314 ,Q350, Q377 and Q379 are non-primary aerated,
insert orifice pilot burners. Q382 is primary aerated
with an insert orifice.
• Variety of mounting brackets available.
• Variety of tip styles to provide desired flame pattern.
• Interchangeable, color-coded orifice and inlet fittings
can be ordered to convert between natural and LP gas.
• Q350, Q377, and Q380 are energy efficient pilot
burners.
• Q380 is for horizontal mounting only.
• Q377, Q379 and Q382 design makes them ideal for use
with any millivolt standing pilot gas valves in fireplace
and space heating applications.
• Electrode assembly available for Piezo ignition on
Q377, Q379 and Q382.
Application ........................................................................... 1
Features .............................................................................. 1
Ordering Information ........................................................... 2
Specifications ...................................................................... 2
Installation ........................................................................... 16
Startup and Checkout ......................................................... 20
Service ................................................................................ 21
PRODUCT DATA
Contents
60-2075-3

Advertisement

loading

Summary of Contents for Honeywell Q314

  • Page 1: Table Of Contents

    PRODUCT DATA FEATURES • Q324 and Q327 are primary aerated, spud orifice pilot burners. • Q314 ,Q350, Q377 and Q379 are non-primary aerated, insert orifice pilot burners. Q382 is primary aerated with an insert orifice. • Variety of mounting brackets available.
  • Page 2: Ordering Information

    Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and...
  • Page 3 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS Table 1. Model Specifications. Recommended Recommended Model Primary Aerated Type of Orifice Pilot Tip Type Thermocouple Thermopile Q314A Insert Target Q309, Q340, Q390 Q313 Q324A Spud Multiport Q309A Q313...
  • Page 4 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 90° 90° 90° 90° 180° THERMOCOUPLE OR THERMOPILE 135° 90° 90° 90° 90° MAIN BURNER IGNITION FLAME Q324 THERMOCOUPLE OR THERMOPILE THERMOCOUPLE MAIN BURNER OR THERMOPILE IGNITER FLAME (2) 20 DEG.
  • Page 5 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 1-1/2 1-1/2 15/32 13/16 11/16 15/32 1-5/32 1-3/32 13/32 25/32 1-5/32 1-1/2 11/16 13/32 11/16 15/32 13/16 1-5/32 13/32 25/32 1-3/16 Milli- Milli- Milli- Milli- Inches meters Inches meters...
  • Page 6 25/32 19.8 INLET FITTING HERE. MAY INCREASE OVERALL HEIGHT. 17/32 13.5 13/16 20.6 9/32 9/16 14.3 27/32 21.4 1/4 IN. COMPRESSION FITTING. M3305 Fig. 4. Q314 No. 11, No. 34, No. 48 and No. 64 mounting brackets and dimensions. 60-2075—3...
  • Page 7 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 7/16 23/32 1-5/32 1-13/32 27/32 7/16 23/32 1-5/32 1-13/32 27/32 Milli- Milli- Milli- Milli- LINT SCREEN - OPTIONAL. Inches meters Inches meters Inches meters Inches meters 1/4 IN. COMPRESSION FITTING.
  • Page 8 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 7/16 23/32 1-5/32 1-13/32 27/32 5/16 No.3 5/16 23/32 1-5/32 27/32 No.5 Milli- Milli- Milli- Milli- LINT SCREEN - OPTIONAL. Inches meters Inches meters Inches meters Inches meters 1/4 IN. COMPRESSION FITTING.
  • Page 9 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 1-1/2 11/32 11/16 15/32 1-1/2 11/16 7/16 13/32 25/32 1-1/2 1-9/16 11/32 11/32 11/16 11/16 19/32 13/32 25/32 11/32 25/32 Milli- Milli- Milli- Milli- SPECIFY WINGSPAN 1, 1 1/4, 1 1/2, 1 3/4, 2, 2 1/4, 2 1/2,...
  • Page 10 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 7/16 25/32 25/32 1-1/2 No. 1 No. 2 Milli- Milli- Milli- Milli- Inches meters Inches meters Inches meters SPECIFY WINGSPAN 1, 1 1/4, 1 1/2, 1 3/4, 2, 2 1/4, 2 1/2,...
  • Page 11 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 7/16 1-1/2 11/32 11/16 1-1/8 1-3/32 13/32 21/32 25/32 25/32 1-9/16 1-1/16 1-1/2 11/32 11/16 5/16 1-3/16 1-3/32 25/32 21/32 7/16 25/32 3/16 1-1/16 1 IN. STANDARD, 1-3/16 IN. RAISED.
  • Page 12 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 13/32 5/16 25/32 1-1/8 No. 35 1-1/2 7/16 2-3/16 1-3/4 7/32 7/16 7/16 3/16 1-1/16 9/32 1-1/8 25/32 25/32 1-15/16 No. 54 No. 66 1 IN. STANDARD, 1-3/16 IN. RAISED.
  • Page 13 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 2-3/16 7/32 1-3/4 7/16 1-13/16 13/16 25/32 No. 75 1 IN. STANDARD, 1-3/16 IN. RAISED. Milli- Milli- Milli- Milli- 25/32 IN (20 mm) STANDARD, 17/32 IN. (14 mm) RAISED.
  • Page 14 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 3/4 (19) 1-7/8 (47) 2-1/4 (57) 1-3/16 1-1/2 NO. 10-32 STANDARD (30) (38) TAPPED HOLES 2-5/16 2-5/16 (13) (59) (59) 3/4 (19) 1-11/16 (43) M11146 Fig. 12. Q377 mounting brackets and dimensions in in. (mm).
  • Page 15 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 1-5/16 (33) MOUNTING HOLES (2) 11/64 IN. DIA (4) 13/32 (CLEARS NO. 8 SCREW) (10) 1/4 (6) 1-11/16 (43) 7/16 (11) 15/32 (12) 1-11/16 (43) 1-17/32 (39) 13/16 (21) 1/4 IN.
  • Page 16: Installation

    Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 2-5/8 (67) 1-11/16 (43) (16) (25) 1-3/16 (30) 3-1/8 (79) 1-11/16 (43) 1-1/2 1-1/2 1-5/16 1-5/16 (33) (38) (38) (33) 2-5/16 (59) 2-5/16 (13) 1/2 (13) (59) NO. 10-32...
  • Page 17 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS WARNING FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH Follow these warnings exactly. Disconnect power supply before wiring to prevent electrical shock or equipment damage.
  • Page 18 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS PILOT BURNER/ PILOT BURNER/ PILOT BURNER/ IGNITION- IGNITION- IGNITION- SENSOR SENSOR SENSOR TOO HIGH JUST RIGHT TOO LOW IGNITION MAIN BURNER IGNITION FLAME JUST MISSES FLAME FLAME MAIN BURNER...
  • Page 19 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS Install Thermocouple or Thermopile Install Bleed Gas Tubing (if used): 1. Route the bleed gas tubing from the bleed tapping on Push-in Design the gas control to the pilot burner.
  • Page 20: Startup And Checkout

    Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS Gas Leak Test PILOT BURNER 1. Ensure that the gas supply is turned on at the appliance ASSEMBLY service valve. 2. Paint the pipe connections upstream of the pilot burner with rich soap and water solution.
  • Page 21: Service

    Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS Ignite Pilot Burner Pilotstat ® Safety Control Power Unit Failure 1. Before lighting the pilot burner, turn the thermostat to its 1. Make sure the pilot flame is properly adjusted.
  • Page 22 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 4. Relight the pilot burner. The power unit should hold in. 5. Turn the gas control knob to the ON position and set the thermostat temperature setting above room temperature.
  • Page 23 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS 60-2075—3...
  • Page 24 Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Inc. Honeywell Limited-Honeywell Limitée Room 3213-3225 Honeywell Plaza 155 Gordon Baker Road Sun Hung Kai Centre P.O.

This manual is also suitable for:

Q324Q327Q379Q350Q380Q382 ... Show all