Project planning information for direct heating

6 Project planning information for direct heating

6 .1 Heating system design

Selection of the burner type is dependent on the fur-
nace temperature.
Recommended
Burner
range of use
[°C]
ECOMAX..C
up to 1250
ECOMAX..M
up to 1100
ECOMAX..F
up to 1000
Burners ECOMAX..M (sizes 1 to 5) and ECOMAX..F can
be used for furnace temperatures up to the max. appli-
cation temperature if it is ensured that the burner head
cannot overheat, e.g. due to burners positioned oppo-
site the ECOMAX or non representative temperature
measurements, see also page 37 (Furnace tempera-
ture measurement).
Selection of the burner size is dependent on the net
heat output. From this, the required burner capacity is
calculated using the firing efficiency value.
Net heat output [kW]
Firing efficiency η
ECOMAX · Edition 10.17
Max. flue gas temperature at
recuperator inlet
[°F]
[°C]
up to 2282
1250
up to 2012
1150
up to 1832
1050
= Burner capacity [kW]
1
0,9
0,8
0,7
0,6
0,5
[°F]
0,4
2282
2102
0,3
1922
0,2
0,1
0
400 500 600 700 800 900 1000 1100
Details on heating system design on request.