DC link components
5.1 Braking Module
5.1.4.4
Installing the Braking Module in a Smart Line Module / Active Line Module / Motor
Module, frame size JX
Figure 5-11
Installing the Braking Module
The steps for the installation procedure are numbered in accordance with the diagram.
1. Insert the Braking Module.
2. Tighten the 4 retaining screws for the Braking Module.
3. Install the connection bracket for the DC link (DCPA/DCNA).
CAUTION
The tightening torques specified in the table "Tightening torques for connecting current-
conducting parts" must be observed.