System overview
1.3 Technical specifications
Permissible ambient and coolant
temperature (air) during operation for DC
link and motor-side power components
Cooling method according to
EN 60146-1-1:1993
Cooling method
Climatic ambient conditions
Storage
1)
Transport
1)
Operation
Environmental class/harmful chemical substances
Storage
1)
Transport
1)
Operation
Organic/biological influences
Storage
1)
Transport
1)
Operation
Degree of pollution
The Safety-Integrated safety function:
The components must be protected against conductive contamination (e.g. by installing them in a cabinet with degree of
protection IP54B to EN 60529).
Provided that conducted interference can be prevented at the installation site, the degree of protection for the cabinet can
be decreased accordingly.
Installation altitude
Certificates
Conformity
Standards
Approvals (only up to 600 V 3 AC)
In transport packaging
1)
26
0 °C to +55 °C up to 2000 m above sea level
Active Interface Modules, Basic Line Modules, Smart Line Modules, Active
Line Modules, Motor Modules: AF
A: Air cooling
F: Forced cooling, drive unit inside the device
Line reactors, sine-wave filters, motor reactors, dv/dt filters with Voltage
Peak Limiter: AN
A: Air cooling
N : Natural cooling (convection)
Internal air cooling,
power units with increased air cooling by built-in fans
Class 1K3 to EN 60721-3-1Temperature: -40 °C to +70 °C
Class 2K4 to EN 60721-3-2, Temperature -40 °C to +70 °C
Max. air humidity 95 % at +40 °C
Class 3K3 to EN 60721-3-3,
Condensation, splashwater and ice formation are not permitted (EN 60204,
Part 1)
Class 1C2 to EN 60721-3-1
Class 2C2 to EN 60721-3-2
Class 3C2 to EN 60721-3-3
Class 1B1 according to EN 60721-3-1
Class 2B1 according to EN 60721-3-2
Class 3B1 according to EN 60721-3-3
2 to EN 61800-5-1
The devices may be operated only in environments with degree of pollution 2
and without condensation. On control cabinets with forced air cooling, foreign
particles must be filtered out of the inflow air through filter mats.
To prevent condensation, the devices can be warmed constantly by heaters.
> 2000 m above sea level without derating
> 2000 ... 4000 m above sea level, see derating characteristics
CE (Low Voltage and EMC Directives)
EN 61800-5-1, EN 60204-1, EN 61800-3, EN 60146-1-1
cULus (File Nos.: E192450 and E214113)