Pvb, Basic Module - Danfoss PVG 100 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 100:
Table of Contents

Advertisement

Technical Information
Technical characteristics

PVB, basic module

PVG 100 Proportional Valve Group
C
Caution
Because of flow forces, cylinder differential areas, Danfoss recommends Ls margins under 25 bar [360 psi].
As noted above, work port flow is dependent upon the Ls margin set on the pump. PC pumps maintain a
constant discharge pressure which is equal to the PC setting on the pump. Hence the Ls margin for PC
pumps can be thought of as the difference between the PC setting and the load pressure. Therefore work
port flow will change with load pressure, thus, pressure compensated flow will not be obtained.
Pressure drop PVB at max. main spool travel
D
D
p
p
psi
bar
PVG 100
900
60
800
50
700
600
40
500
30
400
300
20
200
10
100
0
0
40
80
120 160 200 240 280 320 360 400 440
0
40
50
520L0720 • Rev EB • Jan 2014
A/B
T max spool travel
40
65
130
100
90
60
70
80
150
180
210
240
Q
A/B
l/min
Q
A/B
105
US gal/min
V310203.B
29

Advertisement

Table of Contents
loading