Technical Information
Technical data
PVG 100 Proportional Valve Group
1)
For standard PVG 100 spools.

PVEO

Supply voltage U
rated
DC
range
max. ripple
Current consumption at rated voltage
Input impedance in relation to 0.5 • U
Power consumption

PVEA, PVEH and PVES

Supply voltage U
rated
DC
range
max. ripple
Current consumption at
PVEH/PVES (PVEA)
rated voltage
Signal voltage
neutral
A-port ↔ B-port
Signal current at rated voltage
Input impedance in relation to 0.5 • U
Input capacitor
Power consumption
PVEH/PVES (PVEA)
For detailed information, see PVE actuator catalog, 520L0553.
520L0720 • Rev EB • Jan 2014
12 V
DC
11 V to 15 V
5%
0.65 A @ 12 V
12 KΩ
DC
8 W
11 V to 32 V
11 V to 32 V
5%
0.57 (28) A @ 12 V
0.5 • U
DC
0.25 • U
to 0.75 • U
DC
0.25 mA to 0.70 mA
12 KΩ
DC
100 ηF
7 (3.5) W
24 V
DC
22 V to 30 V
0.33 A @ 24 V
0.3 (15) A @ 24 V
DC
27