Danfoss PVG 100 Technical Information page 31

Proportional valve group
Hide thumbs Also See for PVG 100:
Table of Contents

Advertisement

Technical Information
Technical characteristics
PVG 100 Proportional Valve Group
Oil flow as a function of spool travel for spools A to F - 15 bar [218 psi]
Set pressure difference between pump pressure and LS signal = 15 bar [218 psi] measured at the P-port
of the valve.
PVLP, shock and suction valve
The shock valve PVLP is designed to absorb shock effects. Consequently, it should not be used as a
pressure relief valve. PVLP is set at an oil flow of 10 l/min [2.6 US gal/min].
520L0720 • Rev EB • Jan 2014
PVLP/PVLA, suction valve
31