Functions
3.2 Function diagram for setup and automatic mode
3.2
Function diagram for setup and automatic mode
Requirements
● Start type: Automatic start
● Protective door closed and signal present at P1 and P2
● Magnet of the tumbler provides positive checkback signal (signal to MAG)
max n1
AUTO
min n2
max n3
SETUP
min n4
STANDSTILL
n5
U
S
Start
override
Signal input
Setup mode
EA1
Signal input
Automatic mode
EA2
13/14 and 15
23/24 and 25
Figure 3-1
Function diagram for setup and automatic mode
26
3TK2810-1 safety-related speed monitor
System Manual, 01/2011, 926246402000 DS 02