Circuit diagrams
10.1 Circuit diagram
Application examples
Speed and standstill monitoring using a suitable encoder, automatic mode; in the case of
manual start, on pushbutton at T4/ST; in the case of autostart, jumper at T4/ST; suitable up
to SIL 3, Performance Level e, SK 4 (a requirement for SK 4 is that in the case of longer
standstill times, a forced dormant error detection procedure t < 24 hrs is carried out).
Two-channel speed and standstill monitoring using two NPN or PNP proximity switches,
automatic mode; protective door monitoring active; in the case of manual start, on
pushbutton at T4/ST; in the case of autostart, jumper at T4/ST; suitable up to SIL 3,
Performance Level e, SK 4 (a requirement for SK 4 is that in the case of longer standstill
times, a forced dormant error detection procedure t < 24 hrs is carried out).
Please read the note "Connecting the initiators" in chapter "Product-specific safety
information (Page 9)".