Siemens 3TK2810-1 System Manual page 64

Safety relays, safety-related speed monitor, industrial controls
Hide thumbs Also See for 3TK2810-1:
Table of Contents

Advertisement

Technical data
8.1 Technical data
Performance level (PL) according to
ISO 13849-1
Category
according to EN 954-1
according to ISO 13849-1
Probability of dangerous failure per
hour (PFHD) with high demand rate
according to EN 62061
T1 value for proof test interval or
service life according to IEC 61508
Number of outputs as contact-
affected switching element as NO
contact safety-related/ delayed
switching
as contact-affected switching
element as NC contact for
reporting function instantaneous
switching
as contact-affected switching
element as NO contact safety-
related instantaneous switching
as contact-affected switching
element as NO contact safety-
related/ delayed switching
as contact-less semiconductor
switching element
safety-related
non-delayed
delayed switching
for reporting function
non-delayed
delayed switching
Stop category according to
DIN EN 60204-1
Design of the input
cascading-entrance/operation-
even switching
reducing-entrance
start-up entrance
Design of the electrical connection
jumper socket
64
3TK2810-1BA41 3TK2810-1BA42 3TK2810-1KA41 3TK2810-1KA42
1/h
a
e
4
4
3,38E-9
20
0
1
1
0
0
1
1
0
No
Yes
Yes
Yes
3TK2810-1 safety-related speed monitor
System Manual, 01/2011, 926246402000 DS 02

Advertisement

Table of Contents
loading

Table of Contents