Parameterization And Pin Assignments Of The Rj45 Interface; Copying Parameters - Siemens 3TK2810-1 System Manual

Safety relays, safety-related speed monitor, industrial controls
Hide thumbs Also See for 3TK2810-1:
Table of Contents

Advertisement

6.2.4

Parameterization and pin assignments of the RJ45 interface

The RJ45 interface is used for connecting an encoder to the device with the relevant
configuration of the 3TK2810-1. With the appropriate transfer cable (see accessories), the
interface can also be used to parameterize another device using the copy function. This is
important if the speed monitor is to be used in a standard application, or if it has to be
replaced in the event of a fault.
Figure 6-1
6.2.5

Copying parameters

The parameters can be copied by linking two speed monitors using the transfer cable.
Procedure:
1. Connect both speed monitors with the transfer cable
2. Connect both speed monitors to power supply
3. Select "Copy parameters" in the menu of the "Sending device".
4. Start the copy operation with "Send parameters"
5. The prompt "Receive parameters?" appears on the display of the "Receive device" As
soon as this is acknowledged with "OK" (right softkey), transfer begins.
6. When transfer has been completed, the basic screens appear again on both devices.
7. Disconnect the cable (remove transfer cable).
3TK2810-1 safety-related speed monitor
System Manual, 01/2011, 926246402000 DS 02
Pin assignments of the RJ45 interface
WARNING
Hazardous Voltage.
Can Cause Death, Serious Injury, or Property Damage.
Carry out functional test of the system
To guarantee the safety of the system, a full functional test must be carried out and
successfully concluded after copying the parameters.
Operation
6.2 Parameterizing/configuring
47