the DMX controller. The allocation of this starting address is achieved by setting the correct
number on the display located on the base of the device.
You can set the same starting address for all fixtures or a group of fixtures, or make different
address for each fixture individually.
If you set the same address, all the units will start to "listen" to the same control signal from the
same channel number. In other words, changing the settings of one channel will affect all the
fixtures simultaneously.
If you set a different address, each unit will start to "listen" to the channel number you have set,
based on the quantity of control channels of the unit. That means changing the settings of one
channel will affect only the selected fixture.
In the case of the LED PROFILE, which is a 5 channel fixture, you should set the starting address
of the first unit to 1, the second unit to 6 (5 + 1), the third to 11 (5 + 6), and so on.

8. Control Board

There are four keys on the control panel , which could be used to set the address, turn ON/OFF,
operating the program and reset.
[Mode/Esc] press this key to enter into edit mode. Press this key under the edit mode if you want
to return to previous Mode/Esc. it will exit from edit mode 60 seconds after the last keypress
[UP] screen will flash when pressing this key in normal mode, the adress value will increasing.
Keep pressing this key, the address value will increase rapidly. it will exit from flash 60 seconds
after the last keypress. Press this key under edit mode, you can choose the function you want
from the buttom up in the Mode/Esc.
[DOWN] screen will flash when pressing this key in normal mode, the address value
will idecreasing. Keep pressing this key, the address value will decrease rapidly. it will exit from
flash 60 seconds after the last keypress. Press this key under edit mode, you can choose the
function you want from the top down in the Mode/Esc.
[ENTER] this key is functionless when in normal mode. Press this key under the edit mode, it
will enter into next Mode/Esc.
Address
ValuDisp
SetSlave
AutoProg
TimeInfo
TempInfo
Soft Ver
Stat Set
Serv Set
Disp Set
001~XXX
All Ch....
Slave1,Slave2,Slave3
Master / Alone
Cur Time
TotalHrs
Last Hrs
TimePass
Clr Last
HeadTemp
Ver x.x.x
Addr DMX
NoDMXSta
Password
RDM UID
Off Time
XXXX(Hours)
XXXX(Hours)
XXXX(Hours)
Password=XXX
ON/OFF
XXX /
ON/OFF
CloShut/Hold/Auto
Password=XXX
XXXXXX
10
001~XXX
Warm....
Slave1,Slave2,Slave3
Master / Alone
Power on running time
Fixture running time
Fixture Last times clear
Timer Password 038
Clear Fixture Last time
Temperature in the head
Software version of each IC
Add. via DMX
Auto run if no DMX
Service Password"=050"
RDM PID Code
Display shutoff time
XM1193-V1.0 -E