The ELITEC DTG 1300 Eco.NOx/V boiler is a floor-standing cast
iron gas-fired boiler with an atmospheric burner with very low
pollutant emission with integrated domestic hot water production.
The boiler must only be connected to a chimney.
The design of the cast iron heater body with interleaved spurs gives
very high performance. Also, the baffling in the smoke circuits limits
the natural chimney effect and gives high performance yields.

2 Composition of the range

Heating and domestic hot water
- DTG 1300 Eco.NOx/V or H Panel B:
Boiler with (110 ou 130 l) domestic hot water tank and electronic
command panel
- DTG 1300 Eco.NOx/V or H Panel E:
Boiler with (110 ou 130 l) domestic hot water tank and electronic
command panel with extractable or built-in Easymatic regulator

3 Certifications

3.1
Introduction
97/23/CE Directive
Gas and oil boilers with a maximum operating temperature of 110°C
and hot water tanks with a maximum operating pressure of 10 bar
pertain to article 3.3 of the directive, and therefore, cannot be CE-
marked to certify compliance with the directive 97/23 EC.
De Dietrich boilers and DHW tanks conform to the regulations in
article 3.3 of the 97/23/CEE Directive and is backed by the CE mark
for the 90/396/CEE, 92/42/CEE, 72/73 CEE and 89/336/CEE
directives.
CE identification no: CE-0085BP0002
Type B11
boiler
BS
The boilers leave the factory operating with H natural gas. To operate
with L Natural gas or with propane: see chapter "Adapting to another
gas"
Thermal performance level (according to NFD 30-002): B300
Performance class III boiler according to ATG B 84
recommendations.
Boilers are tested under the LRV-92 standard.
6
France:
Switzerland:

Description

The boilers are equipped with an anti smoke release safety device ;
they may therefore be installed in inhabited areas. It consists of a
thermostat located in the anti-blowback which causes the burner to
stop for 15 minutes. This is indicated by an alarm light flashing on the
control panel. The boiler automatically restarts after 15 minutes if the
cause of the cut off has been removed.
The tightly packed insulation of the boiler equipment reduces losses
into the atmosphere to very low levels.
- DTG 1300 Eco.NOx/V or H Panel D:
Heater with (110 ou 130 l) domestic hot water tank and DIEMATIC
3 electronic command panel
The command panel gives priority to producing domestic hot
water.
DTG 1300 Eco.NOx/V