CONNECTION DIAGRAM

EN

BASIC SYSTEM

BTQ110
TCD 1042
RED
BLACK
CONTROL CABLE
EXTENSIONS
(OPTIONALS)
*
TO THE SERVICES
BATTERY
*
COMMON NEGATIVE FOR THE BATTERY GROUPS.
** WARNING: IN CASE OF OVERTEMPERATURE, THE THERMAL PROTECTION ON THE MOTOR WILL OPEN AND INTERRUPT THE NEGATIVE CONTACT ON THE
SOLENOID UNIT. WAIT AS LONG AS THE SYSTEM NEEDS TO REACTIVATE.
22
TCD 1022
RED
BLACK
SPLITTER
(OPTIONAL)
QUICK
ACCESSORIES FOR ACTIVATION
®
OF THE BOW THRUSTER
CONTROL PANELS
TCD 1022
TCD 1042
TSC MAIN SWITCH
COMMAND
TMS THRUSTER
MAIN SWITCH
S
A
A
+
M1
M2
-
SX
DX
MOTOR
TCD 1044
TCD 1062
BOW
STERN
FUSEHOLDER TFH3
PSS PARALLEL-SERIES
BATTERY SWITCH
**
THERMIC
PROTECTION
*
BATTERY
12/24V
BOW THRUSTER BTQ110-125 IT EN - REV002A