M A I N T E N A N C E G U I D E L I N E S
Draining the water tank: The Entour Ice has a drainage valve built in. To empty the water tank
follow the instructions below:
1. Disconnect all power to the unit
2. With the water at a safe temperature of 86°F (30°C) or below, locate the drain valve at the
base of the unit.
3. Open the drainage valve by turning the blue knob counter clockwise.
4. Once water has drained, close the drain valve by turning the blue knob clockwise.
Non Fuse Breaker (NFB): Each power input (main and auxiliary) has a No Fuse Breaker rated for up
to 20A. If for some reason the NFB becomes tripped, press the breaker to reset the action.
If the breaker does not reset, please contact ADJ Customer Service.
Wheel Lock: The Entour Ice comes with locking casters for easy transportation and
maneuverability. To lock the caster, press down on the locking tab. To unlock the caster, raise the
locking tab so that it is parallel with the ground.