iNSTallaTiON
installation
Re-plugging the coding card
In its delivered condition, the appliance is set to 21 kW. When
changing to a different connected load, carry out the following
steps:
f Re-plug the coding card according to the selected connected
f
load (for selectable connected load and fuse protection of the
appliance, see "Specification / Data table").
f Tick the selected connected load on the type plate. Use a
f
ballpoint pen to do this.
Fitting the base part of the back panel
f Position the lower back panel on the main back panel and
f
click it into place.
f Align the mounted appliance by undoing the fixing toggle,
f
aligning the power supply and back panel, and then re-tight-
ening the fixing toggle. If the back panel is not flush with the
wall, the appliance can be secured at the bottom with two
additional screws.
10
| PEY
3
L3 '
4
L2 '
1
L1 '
2

10.2 Alternative installation methods

10.2.1 Electrical connection from below on unfinished walls
f Fit the cable grommet.
f
Material losses
!
If you break open the wrong knock-out in the back panel
by mistake, you must use a new back panel.
f Break out the cable grommet knock-out in the back panel.
f
Deburr any sharp edges with a file if necessary.
f Reposition the mains terminal in the appliance from the top
f
to the bottom.
f Push the back panel over the threaded stud and the cable
f
grommet. Pull the cable grommet by the locking hooks into
the back panel using pliers, until both locking hooks audibly
click into place.
f Press the back panel firmly into place and lock the fixing tog-
f
gle by turning it clockwise through 90°.