Recommissioning; Appliance Shutdown; Alternative Installation Methods; Electrical Connection From Above On Unfinished Walls - STIEBEL ELTRON DCE-S 6/8 Plus Operation And Installation

Electronically controlled compact instantaneous water heater
Hide thumbs Also See for DCE-S 6/8 Plus:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
iNSTallaTiON

appliance shutdown

f Hook the appliance cover into the appliance back panel at the
f
top rear. Pivot the appliance cover downwards. Check that
the appliance cover is securely seated both top and bottom.
f Secure the appliance cover with the screw.
f
f Remove the protective film from the user interface.
f
f Switch on the power supply.
f
f Ensure that the programming unit is functioning correctly.
f
f Turn the temperature selector to its left-hand and right-hand
f
end-stop.
9.3.1 Appliance handover
f Explain the appliance function to users and familiarise them
f
with how it works.
f Make the user aware of potential dangers, especially the risk
f
of scalding.
f Hand over the instructions.
f
9.4

Recommissioning

Material losses
!
To ensure that the bare wire heating system is not dam-
aged following an interruption to the water supply, the
appliance must be restarted by taking the following steps.
f Disconnect the appliance from the power supply by
f
removing the fuses/tripping the MCBs.
f Open the tap for at least one minute until the appli-
f
ance and its upstream cold water inlet line are free
of air.
f Switch the power back ON.
f
10. Appliance shutdown
f Isolate all poles of the appliance from the power supply.
f
f Drain the appliance (see chapter "Maintenance / Draining the
f
appliance").
10
| DCE-S Plus

11. Alternative installation methods

WARNING Electrocution
Before performing any work on the appliance, discon-
nect all poles from the power supply.
11.1 Electrical connection from above on unfinished
walls
1 Cable grommet
2 Cable routing
f Break out the required aperture in the back panel for the
f
power cable (for positions, see chapter "Specification / Di-
mensions and connections"). Deburr any sharp edges with a
file.
f Cut a hole in the cable grommet to fit the selected connecting
f
cable. Fit the cable grommet.
f Reposition the mains terminal from the bottom to the top.
f
To do so, unclip the mains terminal by pushing it firmly to
the left and pulling it forwards. Turn the mains terminal with
connecting cables 180° clockwise. Lay the internal wiring
under the cable guide. Clip the mains terminal in by pushing
it inwards and to the left until it clicks into place.
f Install the appliance and connect the power cable to the
f
mains terminal as described in chapter "Installation / Stand-
ard installation on finished walls".
11.2 Electrical connection from below on unfinished
walls
1 Cable grommet
1
2
1
www.stiebel-eltron.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dce-s 10/12 plus