iNSTallaTiON
installation
Installing the appliance
3
L3'
4
L2'
1
L1'
2
f Push the back panel over the threaded stud and the cable
f
grommet. Pull the cable grommet by the locking hooks into
the back panel using pliers, until both locking hooks audibly
click into place.
f Remove the protective transport plugs from the water
f
connections.
f Press the back panel firmly into place and lock the fixing tog-
f
gle by turning it clockwise through 90°.
f Screw the water connection pipes with flat gaskets onto the
f
twin connectors.
Material losses
!
The strainer must be fitted for the appliance to function.
f When replacing an appliance, check whether the
f
strainer is installed (see chapter "Maintenance").
www.stiebel-eltron.com
Removing the flow limiter
Material losses
!
If you use a thermostatic valve, the flow limiter must not
be removed.
L1 '
2
1 Plastic profile washer
2 Flow limiter
f Remove the flow limiter and refit the plastic profile washer.
f
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection in conjunction with the re-
movable cable grommet. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3 mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
Observe the type plate. The specified voltage must match
the mains voltage.
f Connect the power cable to the mains terminal (see chapter
f
"Specification / Wiring diagram").