INSTALLATION

Appliance shutdown

11.2.1 Appliance handover
f Explain the appliance function to users and familiarise them
with its operation.
f Make the user aware of potential dangers, especially the risk
of scalding.
f Hand over the instructions.

11.3 Recommissioning

Material losses
!
To ensure that the bare wire heating system is not dam-
aged following an interruption to the water supply, the
appliance must be restarted taking the following steps.
f Disconnect the appliance from the power supply by
removing the fuses/tripping the MCBs.
f Open the tap for a minimum of one minute until the
appliance and its upstream cold water inlet line are
free of air.
f Switch the power back ON.
12. Appliance shutdown
f Isolate all poles of the appliance from the power supply.
f Drain the appliance (see chapter "Installation / Maintenance /
Draining the appliance").

13. Alternative installation methods

Overview of the alternative types of installation
Electrical connection
On unfinished walls, connected from above
Unfinished walls, from below, short power cable
Installation on finished walls
water connection
Installation on finished walls
Other
Installation with offset tiles
Pivoting appliance cover
Horizontal installation of the appliance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
13.1 Electrical connection from above on unfinished
walls
140
30
1 Cable entry installation aid
f Prepare the power cable.
13
| DHB-E LCD
1 Cable routing
f Reposition the mains terminal from the bottom to the top. To
f Replace the cable grommets.
f Install the cable grommet downwards from above.
f Pull the cable grommet over the cable sheath of the power
f Install the appliance on the threaded studs of the wall
f Push the back panel firmly against the wall. Lock the fixing
f Pull the cable grommets into the back panel, until both lock-
f Connect the power cable to the mains terminal.
IP rating
IP 25
IP 25
IP 24
13.2 Electrical connection on unfinished walls with
IP rating
IP 24
IP rating
IP 25
IP 25
IP 24
f Reposition the mains terminal further downwards. To do this,
1
do this, undo the fixing screw. Turn the mains terminal with
connecting cables 180° clockwise. Route the cable around
the cable guide when doing so. Secure the mains terminal in
place.
cable.
mounting bracket.
toggle by turning it 90° clockwise.
ing tabs engage.
WARNING Electrocution
The connecting wires must not protrude beyond the level
of the mains terminal.
short power cable
undo the fixing screw. Secure the mains terminal in place.
1