4.0 INSTALLATION
Install or position the pump to ensure that air fl ow around the
motor and pump is unobstructed. Keep the motor clean to
ensure maximum cooling during operation.
4.1 Pump Mounting
If desired, the pump may be mounted to a fi xed surface. Refer to
Figure 1 for mounting dimensions.
(Note: Reservoir viewed from below)
C
A
1-2 Gal. (4-8 L)
2.5 Gal. (10 L)
inch [mm]
inch [mm]
A
3.75 [95]
11.0 [279]
B
9.00 [229]
12.0 [305]
C
tapped holes,
Ø 0 .34 [8.6] diameter through holes
M8 x 1.25
0.25 [6] deep
Figure 1, Mounting Dimensions
4.2 Air Breather (See Figure 2)
A shipping plug (A) is installed in the breather port on the top of
the reservoir. Before using the pump, replace the shipping plug
(A) with the air breather (B) and adapter fi tting (C).
A
B
C
Figure 2, Air Breather (ZU4 shown, ZE4 and ZE5 similar)
B
5 Gal. (20 L)
10 Gal. (40 L)
inch [mm]
inch [mm]
15.6 [396]
18.9 [480]
12.0 [305]
12.0 [305]
Oil Fill
Plug
Figure 3, Oil Fill Plug
4.3 Oil Level (See Figures 3 and 4)
Check the pump oil level prior to start-up. The reservoir is full
when the oil level is as shown in Figure 4. If necessary, remove
the oil fi ll plug from the cover plate as shown in Figure 3 and add
oil as required.
IMPORTANT: Add oil only when all system components are fully
retracted, or the system will contain more oil than the reservoir
can hold.
Tank is full when
oil level is here.
1 and 2 Gal.
(4 and 8 L)
Figure 4, Oil Reservoir Sight Glass
3
Model ZU4
Oil Fill
Plug
Models ZE4 and ZE5
2.5, 5 and 10 Gal.
(10, 20 and 40 L)