Electrical connection

The unit is preset to work with a volt-
age of single phase 230 V.
Before making the connection make
sure that:
- the energy power available in the us-
er's house is sufficient for the normal
supply of this appliance (see rating
plate).
- the unit is correctly connected to earth
through a suitable plug and accord-
ing to the installation country Laws.
- the socket or the omnipolar switch
used for the connection must be
easilv reached with the installed ap-
pliance.
The appliance is supplied with elec-
tric cable, therefore you will have to fit it
with a standard plug, suitable for the to-
tal electric load shown on the rating
plate. The plug is to be inserted into a
suitable wall socket.
If you wish to directly connect to the
mains, you have to interpose an
omnipolar switch with a minimum open-
ing between contacts of 3 mm, between
the unit and the mains, complying with
the existing regulations.
The brown live wire (originating from
the clamp of the appliance junction box)
must always be connected to the phase
of the mains supply. In any case, the
supply cord must be positioned in such
a way as it does not reach in any point a
temperature higher by 50°C than the
room temperature.
Replacement of the electric
cable
The replacement of electric
cable must be carried out ex-
clusively by the service force
centre or by personnel with
similar competencies, in ac-
cordance with the current
regulations.
Should the supply cord need to be
replaced, use only the following cable
types: H07 RN-F, H05 RN-F, H05 RR-
F, H05 VV-F, H05 V2V2-F (T90), H05
BB-F. It is necessary that the yellow/
green earth wire is about 2 cm longer
than the live and neutral ones (see dia-
gram).
The section of the cable should be
2
3x1,5 mm
minimum.
After the connection, test the heating
elements for about 3 minutes to ensure
that they are working correctly.