Manual Adhesive Weight Placement
62 x Balancing Procedures
Maintaining that distance, rotate the Dataset® arm toward the inner rim surface, and
then apply the adhesive weights to the rim.
NOTE:
If the servo is off (but is enabled in setup), pressing the
"START" button with the hood in the RAISED position will
restart the servo for adhesive weight application.
NOTE:
Manual weight placement is not as accurate as servo-aided
weight placement. Servo-aided weight placement should be
used whenever possible.
NOTE:
If the servo-aided weight placement is enabled, press the
"STOP" button with the hood in the RAISED position to
disable.
To manually place adhesive weights on the rim after spinning, the inner Dataset®
arm should be used to verify the previously inputted distance.
Rotate the wheel until the location arrow of the desired weight plane is green.
Lift the inner Dataset® arm from home position. The "real-time" number displayed
between the two numbers that represent previously inputted data displays the current
reading of the inner Dataset® arm. The arm should be placed in the downward
position on the rim until the real-time number matches the previously inputted data.
NOTE:
Lifting the inner Dataset® arm will trigger the balancer for
dimension input. Do NOT step on the foot pedal or new
dimensions will be entered.