CAUTION:
56 x Balancing Procedures
The BDC laser locator automatically displays a vivid line at bottom dead center after
a wheel has been spun. The laser turns off when the wheel is spun again.
Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
With the servo enabled, attach the adhesive weight for the left weight plane using the
weight amount shown on the LCD. Refer to "Servo-Aided Adhesive Weight
Placement," page 61. If servo is not enabled, BDC placement should be used. Refer
to "Manual Weight Position Measurement," page 59.
If necessary, use the left
page 82.
Return the inner Dataset® arm to the home position.
With the servo enabled, attach the adhesive weight for the right weight plane using
the weight amount shown on the LCD. Refer to "Servo-Aided Adhesive Weight
Placement," page 61. If servo is not enabled, BDC placement should be used. Refer
to "Manual Weight Position Measurement," page 59.
If necessary, use the right
Feature," page 82.
Left and right weight plane displays should show "OK" after check spin.
ADHESIVE WEIGHTS balancing procedure is complete.
to split the weight. Refer to "Split Weight
to split the weight. Refer to "Split Weight
GSP9720JLR Wheel Balancer Operation Instructions
®
Feature,"
®